3Com CS/2500 manual Each pin must be inserted properly into its socket

Page 77

Upgrades 5-13

Replacing Memory

If you ever need to replace memory chips on the motherboard, follow

Chips

this procedure:

1Make sure server power is off and the power cord is unplugged.

2Remove the cover, as described in “Removing the Cover” on page 5-6.

The memory chips are located on the motherboard, near the front of the server, as shown in Figure 5-5. As shipped, all RAM is stored on four chips (each with a 1 MB x 4 configuration) in slots U5, U7, U9, and U11.

3Remove the old memory chips that you want to replace.

Using the thumb and forefinger of one or both hands, grasp the front and back of the chip and gently rock it back and forth until it becomes loose. Lift the chip out of its socket.

As you remove the chip, note exactly how it was oriented. The beveled top edge of the chip faces the left side of the chassis (when viewed from the front of the server).

4Remove a new memory chip from its antistatic foam shipping pad.

If the pins have been bent, carefully straighten them. Orient the chip with the beveled corner closest to the front of the server.

All memory chips must have the same orientation.

CAUTION: Failure to place the memory chips correctly will cause the self-test diagnostics to fail and possible server or memory chip damage when the server is powered on.

5Being careful to line up the pins with the socket, firmly push each memory chip into its socket until it snaps into place.

CAUTION: Be sure that no pins are bent under the body of the chip.

Each pin must be inserted properly into its socket.

6Repeat steps 4 and 5 for the remaining chips.

7Replace the cover, as described in “Replacing the Cover” on page 5-15.

Image 77
Contents CS/2500 Series 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Iii Page Contents Installation Maintenance and Upgrades PIN Assignments Technical Support Page Figures Tables Introduction About this GuideAudience ConventionsThis Typeface Italics Italics are used to denote new terms or emphasis About this Guide Features FeaturesOverview Ten standard RS-232-D electrical interfacesSW/2500, can be used only with the CS/2500 and CS/2600 SoftwareCompatibility Panel, see Back Panel on ChassisHardware Interrupt Front Panel Its +5 V DC output CS/2500 and CS/2600 back panel, shown in -5, contains Power supply module and three types of connectorsBack Panel Overview Back Panel Overview Mount Kit SpecificationsOptional Rack VAC Preparation InstallationDo the following before beginning the installation Installation Install brackets Turning on the server Cabling the ServerTo the Network All ports are set to terminal SETDefault -TERM DeVice = Installation End to the transceiver Slide-lock connection on the serverInstall brackets AC power source must meet the requirements outlined ConfigurationConfiguration, and Appendix C, Monitor Utility ModifyingInstallation Startup Guide or software release notes Diskette Booting fromRbcs files DisketteStartup 3Com Corporation CS/2000 Series Monitor Reading...OK Insert copy and hit return to continue Parameter changes Normal Startup Boot ProblemsMessages Shutting DownShutting Down Startup Firmware Monitor ConfigurationEntering Configuration Following menu is displayed ProcedureChanging SLP Changing the Configuration Configuration Changing the Configuration Next section SLP, and Trivial File Transfer Protocol TftpUsed with 3Com Network Control Servers NCSs Com no longer Tftp Type B Change IP/TFTP Parameters menu appearsConfiguration Bootp Software and to operate in mixed environments Emulating aCS/2000 or CS/2100 Changing Port Configuration Changing Port Configuration Configuration Maintenance Maintenance and Upgrades3Com recommends the following procedures for preventive MaintenanceMaintenance and Upgrades Maintenance Reinstall the fuseholder cartridge in the receptacle Upgrade procedures require you to remove the server cover UpgradesRemoving the Server Cover Rear Grasp both sides of the cover and carefully lift it off8-F Pull taut to expose screw Voltages. There are no user-serviceable parts inside Upgrades Remove Connector from Each pin must be inserted properly into its socket Replace the cover, as described in the next section EPROM. Each pin must be inserted properly into its socketUpgrades Maintenance and Upgrades Troubleshooting Troubleshooting Operating Problems Troubleshooting Memory Dump ProceduresEnter the density of the dump diskettes Return to use the default density 2mb Troubleshooting PIN Assignments Figure A-1 Serial Connector Pin NumberingTXD DTE Transceiver DO-S Slct Startup Messages Appendix B Startup Messages Monitor Utility You can access the monitor in either of the following waysNonfunctional Set the Auto-reboot parameter to Boot monitorContinuous Self-Test and Initial Boot Source parameters -2 on page 1-4. The switch is recessed into a round hole to Memory dumps, refer to Memory Dump Procedures onBecome nonfunctional, enter the following command Dump Procedures onSyntax BT Using this menu, refer to , Configuration Procedures onFilename and address parameters specify the name From memory locationDescription Repeats the previous command 3Com Bulletin Board Service 3ComBBS ServicesTechnical Support On-line TechnicalPress Return to see the ThreeComForum main menu Country Telephone Number Hong Kong 852 2537 44 1442 408 727 Appendix D Technical Support Sender’s expense To obtain an RMA number, call or fax Returning ProductsFor Repair 10/25/95 Numerics IndexCover Index Index Index Index Limited Warranty Bayfront Plaza Santa Clara, CA 408 764-5000 1/1/94