37
Novell NetWare Driver Installation
Upgrading/Changing Driver on an Existing IntraNetWare Server
1To begin the you will need to change the directory to the location of the server and initialize the network server, e.g.,
Type CD \ NWSERVER <ENTER> Type SERVER <ENTER>
2At the NetWare prompt, Type LOAD INSTALL <ENTER>.
3Select Driver Options from the window by highlighting it using the UP or DOWN ARROW keys, press <ENTER>
•Select Configure disk and storage device drivers from the window by high- lighting it using the UP or DOWN ARROW keys, press <ENTER>
4 Highlight Deselect a selected driver and press <ENTER>
5Highlight the driver you wish to replace/upgrade and press <ENTER>
Repeat steps 4 and 5 for each instance of the driver
6When all of the drivers you wish to upgrade/replace have been removed highlight Select an additional driver and press <ENTER>
7Press <INS> followed by <F3>
8Enter the location path of the drivers A:\
9Select the driver you wish to load INI9100.HAM or INI910U.DSK and press <ENTER>
If the HAM driver(s) are being used proceed to step 10. If you use the DSK driver the upgrade is complete and you may exit the install utility.
10Highlight Select and modify parameters and press <ENTER> Enter the slot number and press <F10> to continue
11Highlight Save parameters and continue and press <ENTER>
12Repeat steps 6 through 11 for each additional adapter installed