HandHeld Entertainment SV Series Statement of Agency Compliance, FCC Class B Compliance Statement

Page 3

Statement of Agency Compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and

(2)this device must accept any interference received, including interference that may cause undesired operation.

FCC Class B Compliance Statement

This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio or television technician for help.

Caution: Any changes or modifications made to this device that are not expressly approved by Hand Held Products, Inc. may void the user’s authority to operate the equipment.

Note: To maintain compliance with FCC Rules and Regulations, cables connected to this device must be shielded cables, in which the cable shield wire(s) have been grounded (tied) to the connector shell.

Canadian Notice

This equipment does not exceed the Class B limits for radio noise emissions as described in the Radio Interference Regulations of the Canadian Department of Communications.

Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada.

The CE mark on the product indicates that the system has been tested to and conforms with the provisions noted within the 89/336/EEC Electromagnetic Compatibility Directive and the 73/23/EEC Low Voltage Directive.

Image 3
Contents User’s Guide Disclaimer Statement of Agency Compliance FCC Class B Compliance StatementCanadian Notice Statement of RoHS Compliance SV Series Use with UL-listed EquipmentLaser Beam Enclosure Description Laser SafetyPage Table of Contents Scanner Setup ISO Parameter Grade Thresholds Technical Specifications Chapter a SV Series Setup Hints Scanning Distance and Angle Introduction Quick Check SV SeriesSV100 SV Series Model SpecificationsScanView Software Laser BeamReset Button ConnectorControl Panel Sync Inputs + 5 VDC Power InputIsolated Sync Input Diagram Envelope Sync Mode Edge Sync ModeOutput Ports Communication Sync CommandsCalibration LED Power/Sync LEDIndicator LEDs 1 System DisplaysSerial Port Transmission Format Serial Port ConnectorSerial Port Specifications Serial Port Pin-outPos Chars Parameters + or indicating sign of avg. max. bar Symbology Identifier Table UPC-A Quick Check SV Series User’s Guide ScanView Installation and Setup ScanView Software InstallationSystem Requirements PC Communication Port Setup Menu Bar Screen Display Setup MenuSoftware Operation Warnings Title Bar Screen DisplayLadder Mode and Picket Fence Mode Select SymbologiesStatic Codes Mode Moving Codes ModeAdvanced Menu Support MenuAbout Menu Item Erase Current Session Data Speed Button Bar Screen DisplayAll Data Points, Last 64 Data Points ZoomModes Of Operation Transmit SV CommandsSession Mode Session Mode NotesReflectance Profile Mode Analysis ScreensBar Code Analysis Screen Bottom Panel Bar Code Analysis ScreenBar Code Analysis Results for a Previous Bar Code Graph Display AreaRight Panel Reflectance Profile Screen Color CodingReflectance Profile Screen Scanner Setup Scanner Positioning SV Scanner/Verifier Setup Procedure Bar Code Travel DirectionBar Code Travel Speed Considerations Quick Check SV Series User’s Guide Quick Check SV Series User’s Guide Good Reflectance Profile Bad Reflectance Profile Picket Fence DirectionLadder Direction Picket Fence Bar Code Positioning SpecificationsSetting Ladder Mode Scanning Length Using ScanView Software CalibrationProcedure Adjusting Scanner Gain and Offset Desired Signal Amplitude and Placement Quick Check SV Series User’s Guide Data Match Commands B SV Command LanguageCheck for specific data ~BCa##bc…bbb……mmm……bbb…… etc. up to 32 characters max~ Brnbb .. + Define increment or decrement data check ExamplesDecrementing Examples Incrementing ExamplesRelationship Between ~BC and ~Br Commands Diagnostic Commands DGet the Scan Rate Hardware Configuration Commands H Example return using ScanView~HB# ~HO# Operational Mode Example return using ScanView inputted ~HB5Display the verifier parameters ~HQ# Transmission ModeQuick Check SV Series User’s Guide ~Hdx01nnn Sets scanner gain or offset Label Setup Commands L ~LA## Overall passing grade~LD## Passing percent decode ~LE# ~LFxy Analyze special subsymbology parameters~LL ~LI# Include the specified symbology for a labelQuick Check SV Series User’s Guide ~LQ# Enable or Disable Port Activations by Partial Decodes ~LT# Sync Input Source ~LS## Set minimum number of scans for valid read~LV## Output Interface Mode ~LX# Sync Type~LZ## Set Number of Codes per Label i.e., per sync period ~OS# Set Transmission Data Format Output Mode Selection Commands OOutput Port Setup Commands P ~PBpiiaaabbb Port barcode decision block parametersIDs Analysis Low High Units Parameters Value PCS IDs Description Low Value High Value ~PPpiiaaa Port action parametersPort State PASS/FAIL Parameters Indicator Digit Value ~PR#### Port/LED reset stateIndicator System Control Commands SChecking SV Status with ~HT How to Set Up Single Scan Operation~SK# Communication Sync Execute the calibration procedureDisable Verification Enable VerificationRaster Check Set the number of scans for Software Commanded Read ModeOperation Description ~SN###Reset the System ~Sh## Set the high target reflectance value for calibration~Sl## Set the low target reflectance value for calibration Data Transmission Example ~Ssxy Command ExampleOutput Interface Modes Descriptions Mode 00 ~LV00~Stx Program Command Indicator Header ~Stx Command Example ~St5Mode 01 ~LV01 Mode 01 I/O operationMode 01 LED Operation SV Commands Important to Mode Mode 02 I/O operation Mode 02 ~LV02~LV02 Mode 02 LED Operation~LQ0 Mode 03 ~LV03 Mode 12 ~LV12Mode 12 I/O operation ~LV12 Mode 12 LED Operation~LDxx Mode 16 I/O operation Mode 16 ~LV16Mode 16 LED Operation ~LV16~PP801xxx ~PB811xxxyyy Operation Mode 17 ~LV17SV Commands Important for Mode LED Operation~LV17 ~PB815xxx000 Mode 18 ~LV18 LED Operation ~LV18 ~PB806xxx000 Mode 19 ~LV19 ~LV19 ~LDxx Mode 20 ~LV20 ISO Parameter Grade Thresholds Reference Decode Technical Specifications Qcolvsv Series Product SpecificationsParameter Specification Sync PowerScanning Performance-SV Series Model Scanner OptionsOutputs SymbologiesSync Mode Moving Bar Codes Operation ModesSync Mode Stationary Bar Codes Parameters AnalyzedNo Sync Free Scan Operation Quick Check SV Series User’s Guide Quick Check SV Series User’s Guide Technical Assistance Maintenance/Customer SupportMaintenance CleaningMalaysia Product Service and RepairOnline Technical Assistance For Further Information JapanOnline Product Service and Repair Assistance Limited WarrantyQuick Check SV Series User’s Guide Setting the Proper Scan Distance Session Mode Screen Showing the X Dimension Measurement Setting the Proper Scan AngleButton Example of Good Scan Profile Examples of Scan Profile Parameters Out of Range Calibration HintsQuick Check SV Series User’s Guide Page Hand Held Products, Inc