Output Port Setup Commands – P
A ’~’ immediately followed by a ‘P’ specifies a command from the Output Port Setup category.
Note: The following descriptions of the ~PB and ~PP commands imply all ports are individually programmable. All SV port logic is currently programmed via the Output Interface Mode command ~LV##. See "Output Interface Modes Descriptions" on page
Many of the activation parameters are ISO method calculations. Please see the "ISO Parameter Grade Thresholds" on page
~PBpiiaaabbb
Port barcode decision block parameters.
piiaaabbb = Nine decimal digits representing:
Port- p
ID- ii (See "Table of Analysis Parameters" on page
Low passing threshold- A (aaa)
High passing threshold- B (bbb)
Values for aaa and bbb can be found in the following table:
Values “A” and “B” determine the passing thresholds. If the measured parameter is less than A or greater than B the relevant error flag would be set.
See "Output Interface Modes Descriptions" on page
Table of Analysis Parameters
IDs | Analysis | Low | High | Units | Low | High | |
Parameters | Value | Value | |||||
|
|
|
| ||||
|
|
|
|
|
|
| |
01 | Overall | 0.0 | 4.0 | Grade | 000 | 040 | |
| Grade |
|
|
|
|
| |
|
|
|
|
|
|
| |
02 | Decodabil- | 0 | 100 | % | 000 | 100 | |
| ity |
|
|
|
|
| |
|
|
|
|
|
|
| |
03 | Modulation | 0 | 100 | % | 000 | 100 | |
|
|
|
|
|
|
|
Quick Check® SV Series User’s Guide | 6 - 19 |