HandHeld Entertainment SV Series manual SV Commands Important to Mode

Page 80

Note: Both LEDs can be on in cases where multiple bar codes are analyzed in a sync period.

SV Commands Important to Mode 01

This system is operating in a “mode” rather than fully programmable logic. The port activation parameters are programmable via the ~PB8 rather than ~PB1, ~PB2, etc. for each individual port. Other commands, such as mode commands are also available. The commands most useful for this system application are described below.

~LV01

This command sets this mode of operation.

~Lp0

This command turns off all partial decode logic at the decoder level

~Lp1

This command turns on partial decode logic at the decoder level

~LQ1

This command allows partial decodes to activate the output ports

~LQ0

This command disables partial decodes to activate output ports.

Note: In SV firmware versions x238 and lower, ~LQ commands are not implemented and the command ~HQ1 must be used to disable partial decodes from activating ports. In this case the standard data transmission format is modified, and ScanView will not display data characters correctly.

~LDxx

This command sets the % decode threshold for a passing condition. If analyzing poorly printed symbols, it is recommended that partial decodes be enabled at the decoder level when this command is enabled.

xx= failure threshold. Example ~LD75: if 74% or less of scans on a code were not fully decoded, this sets a failure for this parameter.

~PB816xxx100

This command sets the minimum percent of scans on a code which calculate good quiet zones to determine an acceptable quiet zone analysis. The field xxx is the minimum passing threshold. Example: if xxx = 030, a minimum of 30% of all fully decoded scans on a code must calculate a good quiet zone, or a failure condition is set for this parameter.

~PB806xxx000

This command sets the threshold for the ISO Defects calculation on a code to set a failure condition. The field xxx is the passing threshold for the calculation. For example: if xxx = 025, a Defects analysis of 26% or higher will cause a failure condition for this parameter.

6 - 32

Quick Check® SV Series User’s Guide

Image 80
Contents User’s Guide Disclaimer Canadian Notice Statement of Agency ComplianceFCC Class B Compliance Statement Laser Beam Statement of RoHS ComplianceSV Series Use with UL-listed Equipment Laser Safety Enclosure DescriptionPage Table of Contents Scanner Setup ISO Parameter Grade Thresholds Technical Specifications Chapter a SV Series Setup Hints Scanning Distance and Angle Quick Check SV Series IntroductionSV Series Model Specifications ScanView SoftwareLaser Beam SV100Control Panel Reset ButtonConnector + 5 VDC Power Input Sync InputsIsolated Sync Input Diagram Edge Sync Mode Envelope Sync ModeCommunication Sync Commands Output PortsPower/Sync LED Indicator LEDs 1System Displays Calibration LEDSerial Port Connector Serial Port SpecificationsSerial Port Pin-out Serial Port Transmission FormatPos Chars Parameters + or indicating sign of avg. max. bar Symbology Identifier Table UPC-A Quick Check SV Series User’s Guide System Requirements ScanView Installation and SetupScanView Software Installation PC Communication Port Setup Setup Menu Software Operation WarningsTitle Bar Screen Display Menu Bar Screen DisplaySelect Symbologies Static Codes ModeMoving Codes Mode Ladder Mode and Picket Fence ModeAbout Menu Item Advanced MenuSupport Menu Speed Button Bar Screen Display All Data Points, Last 64 Data PointsZoom Erase Current Session DataTransmit SV Commands Session ModeSession Mode Notes Modes Of OperationBar Code Analysis Screen Reflectance Profile ModeAnalysis Screens Bar Code Analysis Screen Bottom PanelRight Panel Bar Code Analysis Results for a Previous Bar CodeGraph Display Area Color Coding Reflectance Profile ScreenReflectance Profile Screen Scanner Setup Scanner Positioning Bar Code Travel Speed Considerations SV Scanner/Verifier Setup ProcedureBar Code Travel Direction Quick Check SV Series User’s Guide Quick Check SV Series User’s Guide Good Reflectance Profile Picket Fence Direction Bad Reflectance ProfilePicket Fence Bar Code Positioning Specifications Setting Ladder Mode Scanning Length Using ScanView SoftwareCalibration Ladder DirectionProcedure Adjusting Scanner Gain and Offset Desired Signal Amplitude and Placement Quick Check SV Series User’s Guide SV Command Language Data Match Commands B~BCa##bc…bbb……mmm……bbb…… etc. up to 32 characters max Check for specific dataExamples ~ Brnbb .. + Define increment or decrement data checkIncrementing Examples Decrementing ExamplesGet the Scan Rate Relationship Between ~BC and ~Br CommandsDiagnostic Commands D ~HB# Hardware Configuration Commands HExample return using ScanView Example return using ScanView inputted ~HB5 ~HO# Operational Mode~HQ# Transmission Mode Display the verifier parametersQuick Check SV Series User’s Guide ~Hdx01nnn Sets scanner gain or offset ~LD## Passing percent decode Label Setup Commands L~LA## Overall passing grade ~LFxy Analyze special subsymbology parameters ~LE#~LI# Include the specified symbology for a label ~LLQuick Check SV Series User’s Guide ~LQ# Enable or Disable Port Activations by Partial Decodes ~LS## Set minimum number of scans for valid read ~LT# Sync Input Source~LZ## Set Number of Codes per Label i.e., per sync period ~LV## Output Interface Mode~LX# Sync Type Output Mode Selection Commands O ~OS# Set Transmission Data FormatIDs Analysis Low High Units Parameters Value Output Port Setup Commands P~PBpiiaaabbb Port barcode decision block parameters PCS ~PPpiiaaa Port action parameters IDs Description Low Value High ValuePort State PASS/FAIL Parameters ~PR#### Port/LED reset state Indicator Digit ValueSystem Control Commands S IndicatorHow to Set Up Single Scan Operation Checking SV Status with ~HTExecute the calibration procedure Disable VerificationEnable Verification ~SK# Communication SyncSet the number of scans for Software Commanded Read Mode Operation Description~SN### Raster Check~Sl## Set the low target reflectance value for calibration Reset the System~Sh## Set the high target reflectance value for calibration ~Ssxy Command Example Data Transmission ExampleMode 00 ~LV00 ~Stx Program Command Indicator Header~Stx Command Example ~St5 Output Interface Modes DescriptionsMode 01 LED Operation Mode 01 ~LV01Mode 01 I/O operation SV Commands Important to Mode Mode 02 ~LV02 Mode 02 I/O operationMode 02 LED Operation ~LV02~LQ0 Mode 12 I/O operation Mode 03 ~LV03Mode 12 ~LV12 Mode 12 LED Operation ~LV12~LDxx Mode 16 ~LV16 Mode 16 I/O operation~PP801xxx Mode 16 LED Operation~LV16 ~PB811xxxyyy Mode 17 ~LV17 Operation~LV17 SV Commands Important for ModeLED Operation ~PB815xxx000 Mode 18 ~LV18 LED Operation ~LV18 ~PB806xxx000 Mode 19 ~LV19 ~LV19 ~LDxx Mode 20 ~LV20 ISO Parameter Grade Thresholds Reference Decode Parameter Specification Technical SpecificationsQcolvsv Series Product Specifications Power Scanning Performance-SV Series ModelScanner Options SyncSymbologies Sync Mode Moving Bar CodesOperation Modes OutputsNo Sync Free Scan Operation Sync Mode Stationary Bar CodesParameters Analyzed Quick Check SV Series User’s Guide Quick Check SV Series User’s Guide Maintenance/Customer Support MaintenanceCleaning Technical AssistanceProduct Service and Repair Online Technical Assistance For Further InformationJapan MalaysiaLimited Warranty Online Product Service and Repair AssistanceQuick Check SV Series User’s Guide Setting the Proper Scan Distance Setting the Proper Scan Angle Session Mode Screen Showing the X Dimension MeasurementButton Example of Good Scan Profile Calibration Hints Examples of Scan Profile Parameters Out of RangeQuick Check SV Series User’s Guide Page Hand Held Products, Inc