Speed Button Bar – Screen Display
See "Bar Code Analysis Screen" on page 4-9. The buttons on this bar give quick access to various application modes and features.
All Data Points, Last 64 Data Points
, | Toggles the “all data points” mode and the ‘last 64 data points” |
mode. In the ‘last 64 data points” mode, the Graph Display Area (see "Bar Code Analysis Screen" on page 4-9) is updated immediately as the SV scanner/verifier processes each bar code. In the “all data points” mode, bar code processing can continue, but the ScanView display is not updated. The Grade Bar (Color Bar) is dimmed when in All Data Points mode.
Zoom In
Toggles the Zoom-Inmode. First, it switches from Last 64 Data Points mode (see All Data Points, Last 64 Data Points Section above), to All Data Points mode (see All Data Points, Last 64 Data Points Section above). To zoom-in, hold down the left mouse button and drag the mouse-pointer to a desired data point in the Graph Display Area; Hold down the Ctrl-key when the left mouse button is released (then release the Ctrl-key.) The plots are stretched to show only half of the data on each side of the mouse pointer. To zoom further into the data, repeat this process.
Erase Current Session Data
Erases all of the data in the current session. Also, the data in the corresponding hard disk files is deleted.
Reflectance Profile
Scan and Display a new Reflectance Profile. (See "Reflectance Profile Screen" on page 4-12.) The shortcut key for this function is F3.
4 - 6 | Quick Check® SV Series User’s Guide |