11.Error conditions available are:
a.Partial Read (Programmable, ( ~Lp#, LQ#)
b.% decode (Programmable, ~LD##)
c.Bad Quiet Zone: < 10X (~PB816xxx100)
d.ISO Defects grade (Programmable, ~PB806xxx000)
e.ISO Decodability grade (Programmable, ~PB802xxx100)
f.Symbol Contrast grade (Programmable, ~PB804xxx100)
g.Overall ISO Grade (Programmable, ~LAxx)
h.No Read (if sync is received)
i.Number of codes per sync programmable (~LN##, ~LZ##)
j.X dimension Range (Programmable ~PB811xxxyyy)
k.Ratio (Programmable ~PB815xxx000)
l.Symbology Mod Check data error
m.I 2 of 5 optional Mod 10 Check Digit data error (if enabled)
n.Data Match Error (~BC)
o.Increment or Decrement data error (~Br)
LED Operation
1.LED1 will turn on when Ports 1 and 2 are active due to ISO, Symbol Con- trast, X dimension, ratio, mod check or quiet zone error conditions.
2.LED1 will flash when Ports 1 and 2 are active due to a data increment or decrement error condition.
3.LED2 will turn on when Ports 1 and 2 are active due to a partial, % decode or no read error conditions.
4.LED2 will flash when Ports 1 and 2 are active due to a Data Match error condition.
5.Flashing indication will override a solid on indication if both types of error conditions occur.
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in a sync period.
6 - 46 | Quick Check® SV Series User’s Guide |