d.ISO Defects grade programmable (~PB806xxx000)
e.ISO Decodability grade programmable (~PB802xxx100)
f.Symbol Contrast grade programmable (~PB804xxx100)
g.No Read (if edge sync is received)
h.Number of codes per sync programmable (~LN##, ~LZ##)
i.Overall ISO Grade (Programmable, ~LAxx)
j.Symbology modulo check digit
Mode 12 LED Operation
1.LED1 will turn on if Ports
2.LED2 will turn on if Ports
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in a sync period.
SV Commands Important to Mode 12
This system is operating in a “mode” rather than fully programmable logic. The port activation parameters are programmable via the ~PB8 rather than ~PB1, ~PB2, etc. for each individual port. Other commands, such as mode commands are also available. The commands most useful for this system application are described below.
~LV12
This command sets this mode of operation.
~Lp0
This command turns off all partial decode logic at the decoder level
~Lp1
This command turns on partial decode logic at the decoder level
~LQ1
This command allows partial decodes to activate the output ports
~LQ0
This command disables partial decodes to activate output ports.
Quick Check® SV Series User’s Guide | 6 - 37 |