Energy Tech Laboratories EDP70 manual Supply Output Reserve Supply UPS Type

Page 23

 

 

A.C. Supply

Output

Reserve Supply

UPS Type

Vin/Vout

Rated

Protection

Nominal

Nominal

Protection

 

 

current

device

current

current

device

 

 

(A)

(A)

(A)

(A)

(A)

24/12kVA

 

42

50

33

33

50

 

 

 

 

 

 

 

24/18kVA

208/208

60

80

50

50

75

 

 

 

 

 

 

 

24/24kVA

 

78

100

67

67

100

 

 

 

 

 

 

 

36/24kVA

 

78

100

67

67

100

 

 

 

 

 

 

 

36/30kVA

208/208

97

100

83

83

125

 

 

 

 

 

 

 

36/36kVA

 

118

125

100

100

150

 

 

 

 

 

 

 

36/24kVA

 

34

45

67

30

45

 

 

 

 

 

 

 

36/30kVA

480/208

42

50

83

36

55

 

 

 

 

 

 

 

36/36kVA

 

51

70

100

43

65

 

 

 

 

 

 

 

50/30kVA

 

50

70

36

36

50

 

 

 

 

 

 

 

50/40kVA

480/480

66

90

48

48

80

 

 

 

 

 

 

 

50/50kVA

 

83

110

60

60

80

 

 

 

 

 

 

 

50/30kVA

 

50

70

83

36

50

 

 

 

 

 

 

 

50/40kVA

480/208

66

90

111

48

80

 

 

 

 

 

 

 

50/50kVA

 

83

110

139

60

80

 

 

 

 

 

 

 

80/50kVA

 

83

110

60

60

80

 

 

 

 

 

 

 

80/65kVA

480/480

110

125

78

78

100

 

 

 

 

 

 

 

80/80kVA

 

135

150

96

96

125

 

 

 

 

 

 

 

80/50kVA

 

83

110

139

60

80

 

 

 

 

 

 

 

80/65kVA

480/208

110

125

180

78

100

 

 

 

 

 

 

 

80/80kVA

 

135

150

222

96

125

 

 

 

 

 

 

 

MI00/10056 rev.1--05/2001-- page 23

Image 23
Contents EDP70 Plus Important Safety Instructions Read Before Installing ALL CASES, Seek Medical Attention Immediately Contents Figures Summary of the equipment Block diagramIntroduction Summary of the manual24kVA Standard Configuration 480V Functions24/36kVA Ratings Operational modes10 --MI00/10056 rev.1--05/2001 Symbols SafetyGeneral safety Battery safety equipment Electrical precautionsBattery precautions Storage InstallationMechanical characteristics ALL Measurements are Millimeters and Inches NR4 16 --MI00/10056 rev.1--05/2001 Battery Cabinet Drawing for 24/36kVA Ratings 18 --MI00/10056 rev.1--05/2001 Battery Cabinet Drawing for 50/80kVA Ratings 20 --MI00/10056 rev.1--05/2001 Installation Recommended wire sizes Supply Output Reserve Supply UPS Type = 2770 - - - ∙ e 0.125 h Tk / T0 Tr Tk VentilationOutput ConnectionUninterruptible Power System No Unauthorized Operation MI00/10056 rev.1--05/2001-- Electrical connections Table of T& B’s cat.no.s for terminals and crimp tools24 12/18/24kVA Battery CompartmentOutput, Reserve, Input Reserve Ground Primary Input Output External Batteries 36 24/30/36kVA Observe Polarities and Orientations RS232 Female EDP70 Plus 50/80kVA 36 --MI00/10056 rev.1--05/2001 QS1 QS2 QS3 QS4 QS5 Thermostick connector 50/80kVA only Signal connectionsEmergency Power Off Battery charge inhibitedUser Controls Display indicatorsControls LCD Control PanelStart UP SHUT-DOWN Maintenance BypassInstalling the EPO MI00/10056 rev.1--05/2001-- Liquid Crystal Display Visual and Audible AlarmsSilencing Audible Alarm MimicSystem Normal Display Page HeadingsBattery Test Weekly Power History Down to Access Load Time on Reserve xxg xxh xxm xxs Inverter Load System Alarm Abnormal operating mode messagesStop DUE to Overload RECTIFIER/BATTERY Alarms Message Condition Inverter Alarms Message Condition LOAD/RESERVE Alarms Message Condition Power History Matrix Power HistoryResetting data loss manually Battery TestBattery Autonomy Test MI00/10056 rev.1--05/2001-- 11.1 AS400 Computer Interface11.2 RS232 Remote AlarmsBatteries 13.1 EDP70 PLUS/24/18/12 Battery Installation/Start-up13.2 EDP70 PLUS/24/18/12 Optional Battery Cubicle = EDP70 PLUS/24/18/12 Internal Battery Shelves13.4 EDP70 Plus above 20kVA Battery Cubicle Maintenance and Spare Parts13.3 EDP70 Plus above 20kVA Battery Installation/Start-up EDP70 Plus System LOG