Energy Tech Laboratories EDP70 manual RECTIFIER/BATTERY Alarms Message Condition

Page 54

RECTIFIER/BATTERY ALARMS

MESSAGE

CONDITION

NOT CALIBRATED

FAULT

 

 

DC FEEDBACK FAULT

FAULT

 

 

VERIFY DC FEEDBACK

NORMAL

 

 

PRIMARY SUPPLY FAULT

WARNING

 

 

PHASE SEQUENCE ERROR

FAULT

 

 

BATTERY FAULT

FAULT

 

 

PCB SUPPLY FAULT

FAULT

 

 

BATT CONTACTOR OPEN

-

 

 

BATTERY DISCHARGING

WARNING

 

 

SHUTDOWN IMMINENT

WARNING

 

 

DC VOLTAGE HIGH

FAULT

 

 

DC VOLTAGE LOW

WARNING

 

 

INPUT SWITCH OPEN

FAULT

 

 

HARMONIC FILTER OPEN

FAULT

 

 

RECTIFIER ALARM

FAULT

 

 

RECTIFIER INHIBITED

WARNING

 

 

RECTIFIER BLOCKED

FAULT

 

 

BATT. CHARGE INHIBIT

WARNING

 

 

page 54 --MI00/10056 rev.1--05/2001

Image 54
Contents EDP70 Plus Important Safety Instructions Read Before Installing ALL CASES, Seek Medical Attention Immediately Contents Figures Summary of the manual Block diagramIntroduction Summary of the equipment24kVA Standard Configuration Functions 480VOperational modes 24/36kVA Ratings10 --MI00/10056 rev.1--05/2001 Safety General safetySymbols Electrical precautions Battery precautionsBattery safety equipment Installation Mechanical characteristicsStorage ALL Measurements are Millimeters and Inches NR4 16 --MI00/10056 rev.1--05/2001 Battery Cabinet Drawing for 24/36kVA Ratings 18 --MI00/10056 rev.1--05/2001 Battery Cabinet Drawing for 50/80kVA Ratings 20 --MI00/10056 rev.1--05/2001 Installation Recommended wire sizes Supply Output Reserve Supply UPS Type Ventilation = 2770 - - - ∙ e 0.125 h Tk / T0 Tr TkConnection OutputUninterruptible Power System No Unauthorized Operation MI00/10056 rev.1--05/2001-- Table of T& B’s cat.no.s for terminals and crimp tools Electrical connectionsBattery Compartment 24 12/18/24kVAOutput, Reserve, Input Reserve Ground Primary Input Output External Batteries 36 24/30/36kVA Observe Polarities and Orientations RS232 Female EDP70 Plus 50/80kVA 36 --MI00/10056 rev.1--05/2001 QS1 QS2 QS3 QS4 QS5 Battery charge inhibited Signal connectionsEmergency Power Off Thermostick connector 50/80kVA onlyDisplay indicators ControlsUser Controls Control Panel LCDStart UP Maintenance Bypass Installing the EPOSHUT-DOWN MI00/10056 rev.1--05/2001-- Mimic Visual and Audible AlarmsSilencing Audible Alarm Liquid Crystal DisplayDisplay Page Headings System NormalBattery Test Weekly Power History Down to Access Load Time on Reserve xxg xxh xxm xxs Inverter Load Abnormal operating mode messages System AlarmStop DUE to Overload RECTIFIER/BATTERY Alarms Message Condition Inverter Alarms Message Condition LOAD/RESERVE Alarms Message Condition Power History Power History MatrixBattery Test Battery Autonomy TestResetting data loss manually MI00/10056 rev.1--05/2001-- Computer Interface 11.1 AS400Remote Alarms 11.2 RS23213.1 EDP70 PLUS/24/18/12 Battery Installation/Start-up Batteries= EDP70 PLUS/24/18/12 Internal Battery Shelves 13.2 EDP70 PLUS/24/18/12 Optional Battery CubicleMaintenance and Spare Parts 13.3 EDP70 Plus above 20kVA Battery Installation/Start-up13.4 EDP70 Plus above 20kVA Battery Cubicle EDP70 Plus System LOG