IMPORTANT SAFETY INSTRUCTIONS

READ BEFORE INSTALLING

1) SAVE THESE INSTRUCTIONS

This manual contains important instructions for the EDP70 PLUS which should be followed during installation and maintenance of the UPS and associated batteries.

2)The installation must be inspected by trained technicians. The instructions must be followed.

3)When external batteries are provided by the Customer and not Chloride, reference must be made

to

the installation instructions provided by the battery supplier.

WARNINGS

1)The AC and DC supplies to the EDP70 PLUS UPS and the AC output from the UPS MUST be fed through suitably rated circuit breakers or fuses and isolating switches suitable for branch circuit operation.

2)Any external battery cabinet connected to the UPS MUST be provided with an over-current protection device per UL1778 Par. No. 10.4

3)To reduce the risk of fire or electric shock, the equipment must be installed indoors, in a humidity and temperature controlled environment which is free from conductive contaminants.

SAFETY

1)DO NOT REMOVE COVERS DURING NORMAL OPERATION. The panels will be removed during installation, however this should only be undertaken by qualified technicians. It should be ensured

that the UPS is switched off and that all power sources are disconnected (A.C. mains and Battery) before either the rear or side panels are removed.

2)FOREIGN OBJECTS MUST NOT BE INTRODUCED INTO THE VENTILLATION GRILLES. HAZARDOUS VOLTAGES are present within the EDP70 PLUS even when it is switched off.

3)Fuses must ONLY be replaced with the same type and rating.

4)The EDP70 PLUS contains a battery which can be DANGEROUS if interfered with. Contact the supplier for replacement.

5)The UPS and/or its components must be disposed of as notifiable waste in accordance with local pollution control (special waste) regulations.

page 2 --MI00/10056 rev.1--05/2001

Image 2
Contents EDP70 Plus Important Safety Instructions Read Before Installing ALL CASES, Seek Medical Attention Immediately Contents Figures Summary of the manual Block diagramIntroduction Summary of the equipment24kVA Standard Configuration Functions 480VOperational modes 24/36kVA Ratings10 --MI00/10056 rev.1--05/2001 Symbols SafetyGeneral safety Battery safety equipment Electrical precautionsBattery precautions Storage InstallationMechanical characteristics ALL Measurements are Millimeters and Inches NR4 16 --MI00/10056 rev.1--05/2001 Battery Cabinet Drawing for 24/36kVA Ratings 18 --MI00/10056 rev.1--05/2001 Battery Cabinet Drawing for 50/80kVA Ratings 20 --MI00/10056 rev.1--05/2001 Installation Recommended wire sizes Supply Output Reserve Supply UPS Type Ventilation = 2770 - - - ∙ e 0.125 h Tk / T0 Tr TkConnection OutputUninterruptible Power System No Unauthorized Operation MI00/10056 rev.1--05/2001-- Table of T& B’s cat.no.s for terminals and crimp tools Electrical connectionsBattery Compartment 24 12/18/24kVAOutput, Reserve, Input Reserve Ground Primary Input Output External Batteries 36 24/30/36kVA Observe Polarities and Orientations RS232 Female EDP70 Plus 50/80kVA 36 --MI00/10056 rev.1--05/2001 QS1 QS2 QS3 QS4 QS5 Battery charge inhibited Signal connectionsEmergency Power Off Thermostick connector 50/80kVA onlyUser Controls Display indicatorsControls Control Panel LCDStart UP SHUT-DOWN Maintenance BypassInstalling the EPO MI00/10056 rev.1--05/2001-- Mimic Visual and Audible AlarmsSilencing Audible Alarm Liquid Crystal DisplayDisplay Page Headings System NormalBattery Test Weekly Power History Down to Access Load Time on Reserve xxg xxh xxm xxs Inverter Load Abnormal operating mode messages System AlarmStop DUE to Overload RECTIFIER/BATTERY Alarms Message Condition Inverter Alarms Message Condition LOAD/RESERVE Alarms Message Condition Power History Power History MatrixResetting data loss manually Battery TestBattery Autonomy Test MI00/10056 rev.1--05/2001-- Computer Interface 11.1 AS400Remote Alarms 11.2 RS23213.1 EDP70 PLUS/24/18/12 Battery Installation/Start-up Batteries= EDP70 PLUS/24/18/12 Internal Battery Shelves 13.2 EDP70 PLUS/24/18/12 Optional Battery Cubicle13.4 EDP70 Plus above 20kVA Battery Cubicle Maintenance and Spare Parts13.3 EDP70 Plus above 20kVA Battery Installation/Start-up EDP70 Plus System LOG