Configuration. Please wait... | detected and is being processed. |
|
BIOS Update Attempt Failed! | Remote BIOS update attempt failed. | Retry the BIOS update. If problem persists, see Getting Help. |
|
|
|
Caution! NVRAM_CLR jumper is installed | NVRAM_CLR jumper is installed. CMOS has | Remove NVRAM_CLR jumper. See Figure |
on system board. | been cleared. | location. |
CPUs with different cache sizes | Microprocessors with different cache sizes are | Ensure that all microprocessors have the same cache size and |
detected! | installed. | that they are properly installed. See Processors. |
|
|
|
Decreasing available memory | Faulty or improperly installed memory modules. | See Troubleshooting System Memory. |
|
|
|
Error: Incorrect memory configuration | The DIMM group for CPU n is incorrectly | See General Memory Module Installation Guidelines for memory |
| configured and caused the system to halt. | configuration information. If the problem persists, see |
CPU n |
| Troubleshooting System Memory. |
|
| |
|
|
|
!!*** Error: Remote Access Controller | Remote Access Controller initialization failure | Ensure that the Remote Access Controller is properly installed. |
initialization failure *** RAC virtual |
| See Installing a RAC Card. |
USB devices may not be available... |
|
|
|
|
|
Gate A20 failure | Faulty keyboard controller; faulty system | See Getting Help. |
| board. |
|
General failure | The operating system is unable to carry out | This message is usually followed by specific information. Note |
| the command. | the information, and take the appropriate action to resolve the |
|
| problem. |
|
|
|
HyperTransport error caused a system | A fatal system error occurred and caused the | Check the SEL for information that was logged during the |
reset! Please check the system event | system to reboot. | error. See the applicable troubleshooting section in |
log for details! |
| Troubleshooting Your System for any faulty components |
|
| specified in the SEL. |
Invalid NVRAM configuration, Resource | System detected and corrected a resource | No action is required. |
conflict. |
| |
|
|
|
Invalid PCIe card found in the | The system halted because an invalid PCIe | Remove the PCIe expansion card and install either the internal |
Internal_Storage slot! | expansion card is installed in the dedicated | SAS controller in the dedicated slot. |
| storage controller slot. |
|
Keyboard Controller failure | Faulty keyboard controller; faulty system board | See Getting Help. |
|
|
|
Manufacturing mode detected | System is in manufacturing mode. | Reboot to take the system out of manufacturing mode. |
|
|
|
Memory address line failure at address, | Faulty or improperly installed memory modules. | See Troubleshooting System Memory. |
read value expecting value |
|
|
Memory double word logic failure at |
|
|
address, read value expecting value |
|
|
Memory odd/even logic failure at |
|
|
address, read value expecting value |
|
|
Memory write/read failure at address, |
|
|
read value expecting value |
|
|
|
|
|
Memory tests terminated by keystroke. | POST memory test terminated by pressing the | Information only. |
| spacebar. |
|
|
|
|
No boot device available | Faulty or missing optical drive subsystem, hard | Use a bootable USB key, CD, or hard drive. If the problem |
| drive, or | persists, see Troubleshooting an SD Card or Internal USB Key |
| USB key installed. | and Troubleshooting a Hard Drive. See Using the System Setup |
|
| Program for information on setting the order of boot devices. |
|
|
|
No boot sector on hard drive | Incorrect configuration settings in System | Check the |
| Setup program, or no operating system on | Setup program. See Using the System Setup Program. If |
| hard drive. | necessary, install the operating system on your hard drive. |
|
| See your operating system documentation. |
|
|
|
No timer tick interrupt | Faulty system board. | See "Getting Help." |
|
|
|
Optical drive not found | Cable is not properly seated, or drive missing. | See Troubleshooting an Optical Drive. |
|
|
|
PCI BIOS failed to install | PCIe device BIOS (Option ROM) checksum | Reseat the expansion card(s). Ensure that all appropriate |
| failure detected during shadowing. | cables are securely connected to the expansion card(s). If the |
|
| problem persists, see Troubleshooting Expansion Cards. |
| Cables to expansion card(s) loose; faulty or |
|
| improperly installed expansion card(s). |
|
|
|
|
PCIe Degraded Link Width Error: | Faulty system board or riser board. | See Getting Help. |
Embedded device |
|
|
Expected Link Width is n |
|
|
Actual Link Width is n |
|
|
|
|
|
PCIe Degraded Link Width Error: | The specified PCIe device is faulty or | For a SAS controller daughter card, reseat the card in the |
Integrated device | improperly installed. | dedicated PCIe connector. See Installing a SAS Controller |
|
| Daughter Card. If the problem persists, see Getting Help. |
Expected Link Width is n |
|
|
Actual Link Width is n |
|
|
|
|
|
PCIe Degraded Link Width Error: Slot n | Faulty or improperly installed PCIe card in the | Reseat the PCIe card in the specified slot number. See |
| specified slot. | Expansion Cards. If the problem persists, see Getting Help. |
Expected Link Width is n |
|
|
Actual Link Width is n |
|
|
|
|
|
PCIe Training Error: Embedded device | Faulty system board or riser board. | See Getting Help. |
|
|
|
|
|
|