Dell R805 manual Memory Sparing Support, Installing Memory Modules, Memory Sparing Configurations

Page 47

8 GB

2 GB

 

 

12 GB

2 GB

1 GB

 

 

 

 

 

16 GB

2 GB

2 GB

 

 

 

 

 

24 GB

2 GB

2 GB

1 GB

 

 

 

 

32 GB

2 GB

2 GB

2 GB

 

 

 

 

16 GB

4 GB

 

 

 

 

 

 

24 GB

4 GB

2 GB

 

32 GB

4 GB

4 GB

 

 

 

 

 

48 GB

4 GB

4 GB

2 GB

 

 

 

 

64 GB

4 GB

4 GB

4 GB

 

 

 

 

32 GB

8 GB

 

 

 

 

 

 

48 GB

8 GB

4 GB

 

 

 

 

 

64 GB

8 GB

8 GB

 

 

 

 

 

96 GB

8 GB

8 GB

4 GB

 

 

 

 

128 GB

8 GB

8 GB

8 GB

Memory Sparing Support

Memory sparing is supported in systems that have one of the fully populated memory configurations shown in Table 3-1. The memory sparing feature must be enabled in the Memory Information screen of the System Setup program. See Using the System Setup Program.

NOTE: The Memory sparing and node interleaving features cannot be used at the same time. To use memory sparing, you must disable the Node Interleaving option in the System Setup program.

Memory sparing is applied independently to the two groups of DIMMs on opposite sides of the processor sockets. To support memory sparing, all DIMM sockets within a DIMM group must be populated.

When enabled, memory sparing allocates and reserves ranks of memory from the installed DIMMs to act as spare memory in the event of a memory channel failure. A memory channel uses paired DIMMs; for memory sparing to work, DIMMs must be paired as spares also.

Memory sparing allocates only the first rank of memory of a DIMM. For a single-rank DIMM, the entire capacity of the DIMM must be allocated for sparing along with the adjacent single-rank DIMM to spare a memory channel. For dual-rank DIMMs, two DIMMs are also required for sparing, but as only the first rank of each DIMM is allocated, only half of a dual-rank DIMM's capacity is allocated for sparing. The second ranks on both DIMMs are available memory.

Memory sparing calculates the appropriate DIMMs to spare by searching the DIMM sockets, starting with the higher-numbered socket pair (specifically, sockets 3 and 4 or sockets 7 and 8), for an amount of memory large enough to spare one of the available channels of memory. If the DIMMs in these sockets are sufficient to spare a channel of the available memory, the first rank of each of those two DIMMs are spared. If the amount of memory is not large enough to spare an available memory channel, the system spares the DIMM ranks in the lower-numbered sockets. Table 3-2 shows how memory sparing works in various memory configurations.

Table 3-2. Memory Sparing Configurations

 

 

DIMMs

 

 

 

 

 

 

 

Available Memory

Spared

A1, A2, B1, B2

A3, A4, B3, B4

A5, A6, B5, B6

A7, A8, B7, B8

 

 

 

 

 

Memory

512 MB

512 MB

512 MB

512 MB

6 GB

2 GB

 

 

 

 

 

 

1 GB

1 GB

1 GB

1 GB

12 GB

4 GB

 

 

 

 

 

 

2 GB

2 GB

2 GB

2 GB

28 GB

4 GB

 

 

 

 

 

 

4 GB

4 GB

4 GB

4 GB

56 GB

8 GB

 

 

 

 

 

 

8 GB

8 GB

8 GB

8 GB

112 GB

16 GB

 

 

 

 

 

 

 

Indicates a spared single-rank DIMM (512-MB or 1-GB). The entire capacity of this DIMM is reserved for sparing.

 

 

 

 

Indicates a spared dual-rank DIMM (2-GB and higher). One-half of this DIMM's capacity is reserved for sparing.

Installing Memory Modules

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2.Open the system. See Opening the System.

3.Remove the memory cooling shroud. See Removing the Memory Module Cooling Shrouds.

Image 47
Contents Page Other Information You May Need Accessing System Features During StartupKeystrokes for Accessing System Features Back to ContentsIndicator, Button, or Icon Description Connector Front-Panel Features and IndicatorsCondition Drive-Status Indicator Pattern Back-Panel Features and IndicatorsHard-Drive Indicator Codes Hard-Drive Indicator Patterns for RAIDRedundant Power Supply Indicators Power Indicator CodesNIC Indicator Codes Connecting External DevicesLCD Status Messages NIC Indicator CodesIndicator Indicator Code LCD Status MessagesSee Troubleshooting the Microprocessors See Troubleshooting System Cooling ProblemsTroubleshooting System Cooling Problems Troubleshooting the MicroprocessorsDaughter Card See Troubleshooting a Hard DriveInstall memory. See Installing Memory Modules See Troubleshooting System MemorySystem Messages Solving Problems Described by LCD Status MessagesSystem Messages Removing LCD Status MessagesTroubleshooting a Hard Drive. See Using the System Setup Troubleshooting System MemorySee Installing a RAC Card Troubleshooting Your System for any faulty componentsSee Troubleshooting the System Battery USB Device, or Troubleshooting a Hard Drive forSee Troubleshooting a USB Device or Troubleshooting a Hard Combination. See Installing a ProcessorAlert Messages Diagnostics MessagesBack to Contents Running the System Diagnostics Using Server Administrator DiagnosticsSystem Diagnostics Features When to Use the System DiagnosticsSystem Diagnostics Testing Options Using the Custom Test OptionsSelecting Devices for Testing Selecting Diagnostics OptionsVisit support.dell.com Contacting DellContacting Dell Glossary Page Page System memory See RAM Back to Contents Installing System Components Front Bezel Recommended ToolsInside the System Opening the System Opening and Closing the SystemRemoving the Front Bezel Replacing the Front BezelClosing the System Hard DrivesRemoving a Hot-Plug Hard Drive Installing a Drive BlankInstalling a Hot-Plug Hard Drive Removing a Drive BlankRemoving a Hard Drive From a Hard-Drive Carrier Installing a Hard Drive Into a Drive CarrierReplacing a Hard-Drive Carrier Removing a Power Supply Power SuppliesInternal SD Card Replacing a Power SupplyRemoving the Power Supply Blank Installing the Power Supply BlankRemoving a System Fan Installing the SD CardSystem Fans Replacing a Cooling Fan Installing a SAS Controller Daughter CardSAS Controller Daughter Card 11. SAS Controller Daughter Card Cabling Removing a SAS Controller Daughter CardInstalling a RAID Battery RAID BatteryConfiguring the Boot Device Internal USB Memory Key ConnectorExpansion Cards Installing the Optional Internal USB Memory KeyRemoving an Expansion Card Expansion Card Installation GuidelinesInstalling an Expansion Card Removing the Memory Module Cooling Shrouds Cooling ShroudsRemoving the Processor Cooling Shroud Installing the Processor Cooling ShroudInstalling the Memory Module Cooling Shrouds Replacing the Fan Bracket Fan BracketsRemoving the Fan Brackets Replacing Expansion-Card Riser Expansion-Card RisersRemoving Expansion-Card Riser 18. Removing and Replacing Expansion-Card Riser Removing the Riser 2 Board From the Expansion-Card BracketRemoving the RAC Card RAC CardReplacing the Riser 2 Board on the Expansion-Card Bracket 20. Removing and Installing a RAC Card Installing a RAC CardRemoving the LOM Daughter Card LOM Daughter Card Removing the Optical Drive from the System Installing the Optical Drive Optical Drive Replacing the LOM Daughter CardRemoving the Optical Drive From the Optical Drive Tray 22. Removing and Installing the Optical Drive TraySystem Memory Installing an Optical Drive Into the Optical Drive TrayGeneral Memory Module Installation Guidelines Memory ConfigurationsMemory Sparing Support Installing Memory ModulesMemory Sparing Configurations Removing Memory Modules 25. Installing and Removing a Memory ModuleRemoving a Processor Integrated NIC TOEProcessors 26. Installing and Removing the Heat Sink Installing a ProcessorReplacing the System Battery System BatteryRemoving the Sideplane Board Sideplane BoardRemoving the SAS/SATA Backplane Board Installing the Sideplane BoardSAS/SATA Backplane Board Installing the SAS/SATA Backplane Board Control Panel AssemblyInstalling the Control Panel Assembly Removing the Control Panel AssemblyRemoving the System Board System BoardReplace the sideplane. See Installing the Sideplane Board Installing the System BoardSystem Board Jumpers Jumper Setting DescriptionConnector Description System Board ConnectorsSideplane Board Connectors SAS/SATA Backplane Board ConnectorsOpen the system. See Opening and Closing the System Disabling a Forgotten PasswordExpansion-Card Riser-Board Components and PCIe Buses Back to Contents Using the System Setup Program Entering the System Setup ProgramSystem Setup Options Responding to Error MessagesMemory Information Screen System Setup Program OptionsUsing the System Password and Using the Setup Password Memory Information ScreenCPU Information Screen CPU Information ScreenIntegrated Devices Screen Serial Communication Screen Options Serial Communication ScreenSystem Security Screen Integrated Devices Screen OptionsExit Screen System and Setup Password FeaturesEnabled DisabledAssigning a System Password Using the System PasswordDeleting or Changing an Existing System Password Using the Setup PasswordSee Disabling a Forgotten Password Baseboard Management Controller ConfigurationEntering the BMC Setup Module BMC Setup Module OptionsChecking the Equipment Safety First-For You and Your SystemTroubleshooting IRQ Assignment Conflicts Start-Up RoutineIRQ Line Assignment Troubleshooting External ConnectionsTroubleshooting the Video Subsystem IRQ Assignment DefaultsTroubleshooting the Mouse Troubleshooting Basic I/O FunctionsTroubleshooting the Keyboard Troubleshooting a USB Device Troubleshooting a Serial I/O DeviceClose the system. See Opening and Closing the System Troubleshooting a NICTroubleshooting a Wet System Troubleshooting the System Battery Troubleshooting a Damaged SystemTroubleshooting System Cooling Problems Troubleshooting Power SuppliesTroubleshooting a Fan Troubleshooting System MemoryTroubleshooting an SD Card or Internal USB Key Troubleshooting an External Tape Drive Troubleshooting an Optical DriveRemove the bezel. See Removing the Front Bezel Troubleshooting a Hard DriveTroubleshooting a SAS Controller Daughter Card Troubleshooting Expansion Cards Troubleshooting the Microprocessors