3.Remove the memory cooling shroud. See Removing the Memory Module Cooling Shrouds.

NOTICE: Never remove the memory cooling shroud without first powering down the system. Overheating of the system can develop quickly resulting in a shutdown of the system and the loss of data.

4. Locate the memory module sockets on the system board. See Figure 6-2.

CAUTION: The DIMMs are hot to the touch for some time after the system has been powered down. Allow the DIMMs to cool before handling them. Handle the DIMMs by the card edges, and avoid touching the DIMM components.

5.Press down and out on the ejectors on each end of the socket until the memory module pops out of the socket. See Figure 3-25.

6.Replace the memory cooling shroud. See Installing the Processor Cooling Shroud.

NOTICE: Never operate your system with the memory cooling shroud removed. Overheating of the system can develop quickly resulting in a shutdown of the system and the loss of data.

7. Close the system. See Closing the System.

Integrated NIC TOE

The TCP/IP Offload Engine (TOE) functionality of the system's integrated NIC is activated by the LOM NIC hardware key installed in the TOE_KEY socket on the system board (see Figure 6-2.) See the user documentation that came with this system for information on how to set up and configure the TOE feature.

Processors

You can upgrade your processors to take advantage of future options in speed and functionality. Each processor and its associated internal cache memory are contained in a land grid array (LGA) package that is installed in a ZIF socket on the system board.

Removing a Processor

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Prior to upgrading your system, download the latest system BIOS version on support.dell.com.

2.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3.Open the system. See Opening the System.

4.Remove the memory module cooling shrouds. See Removing the Memory Module Cooling Shrouds.

5.Remove the expansion cards from expansion-card riser 2. See Removing an Expansion Card.

6.Remove expansion-card riser 2. See Removing Expansion-Card Riser 2.

7.Remove the processor cooling shroud. See Removing the Processor Cooling Shroud.

NOTICE: Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper thermal conditions.

8.Using a #2 Phillips screwdriver, loosen one of the two heat-sink retention screws. See Figure 3-26.

9.Wait 30 seconds for the heat sink to loosen from the processor.

10.Loosen the other heat-sink retention screw.

11.Gently lift the heat sink off of the processor and set the heat sink aside.

NOTICE: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped.

Image 49
Contents Page Keystrokes for Accessing System Features Accessing System Features During StartupBack to Contents Other Information You May NeedIndicator, Button, or Icon Description Connector Front-Panel Features and IndicatorsHard-Drive Indicator Codes Back-Panel Features and IndicatorsHard-Drive Indicator Patterns for RAID Condition Drive-Status Indicator PatternNIC Indicator Codes Power Indicator CodesConnecting External Devices Redundant Power Supply IndicatorsIndicator Indicator Code NIC Indicator CodesLCD Status Messages LCD Status MessagesTroubleshooting System Cooling Problems See Troubleshooting System Cooling ProblemsTroubleshooting the Microprocessors See Troubleshooting the MicroprocessorsInstall memory. See Installing Memory Modules See Troubleshooting a Hard DriveSee Troubleshooting System Memory Daughter CardSystem Messages Solving Problems Described by LCD Status MessagesRemoving LCD Status Messages System MessagesSee Installing a RAC Card Troubleshooting System MemoryTroubleshooting Your System for any faulty components Troubleshooting a Hard Drive. See Using the System SetupSee Troubleshooting a USB Device or Troubleshooting a Hard USB Device, or Troubleshooting a Hard Drive forCombination. See Installing a Processor See Troubleshooting the System BatteryAlert Messages Diagnostics MessagesBack to Contents System Diagnostics Features Using Server Administrator DiagnosticsWhen to Use the System Diagnostics Running the System DiagnosticsSelecting Devices for Testing Using the Custom Test OptionsSelecting Diagnostics Options System Diagnostics Testing OptionsContacting Dell Contacting DellVisit support.dell.com Glossary Page Page System memory See RAM Back to Contents Installing System Components Inside the System Recommended ToolsFront Bezel Removing the Front Bezel Opening and Closing the SystemReplacing the Front Bezel Opening the SystemClosing the System Hard DrivesInstalling a Hot-Plug Hard Drive Installing a Drive BlankRemoving a Drive Blank Removing a Hot-Plug Hard DriveReplacing a Hard-Drive Carrier Installing a Hard Drive Into a Drive CarrierRemoving a Hard Drive From a Hard-Drive Carrier Removing a Power Supply Power SuppliesRemoving the Power Supply Blank Replacing a Power SupplyInstalling the Power Supply Blank Internal SD CardSystem Fans Installing the SD CardRemoving a System Fan SAS Controller Daughter Card Installing a SAS Controller Daughter CardReplacing a Cooling Fan 11. SAS Controller Daughter Card Cabling Removing a SAS Controller Daughter CardConfiguring the Boot Device RAID BatteryInternal USB Memory Key Connector Installing a RAID BatteryExpansion Cards Installing the Optional Internal USB Memory KeyInstalling an Expansion Card Expansion Card Installation GuidelinesRemoving an Expansion Card Removing the Memory Module Cooling Shrouds Cooling ShroudsInstalling the Memory Module Cooling Shrouds Installing the Processor Cooling ShroudRemoving the Processor Cooling Shroud Removing the Fan Brackets Fan BracketsReplacing the Fan Bracket Removing Expansion-Card Riser Expansion-Card RisersReplacing Expansion-Card Riser 18. Removing and Replacing Expansion-Card Riser Removing the Riser 2 Board From the Expansion-Card BracketReplacing the Riser 2 Board on the Expansion-Card Bracket RAC CardRemoving the RAC Card 20. Removing and Installing a RAC Card Installing a RAC CardRemoving the LOM Daughter Card LOM Daughter CardOptical Drive Installing the Optical DriveReplacing the LOM Daughter Card Removing the Optical Drive from the SystemRemoving the Optical Drive From the Optical Drive Tray 22. Removing and Installing the Optical Drive Tray General Memory Module Installation Guidelines Installing an Optical Drive Into the Optical Drive Tray Memory Configurations System MemoryMemory Sparing Configurations Installing Memory ModulesMemory Sparing Support Removing Memory Modules 25. Installing and Removing a Memory ModuleProcessors Integrated NIC TOERemoving a Processor 26. Installing and Removing the Heat Sink Installing a ProcessorReplacing the System Battery System BatteryRemoving the Sideplane Board Sideplane BoardSAS/SATA Backplane Board Installing the Sideplane BoardRemoving the SAS/SATA Backplane Board Installing the SAS/SATA Backplane Board Control Panel AssemblyInstalling the Control Panel Assembly Removing the Control Panel AssemblyRemoving the System Board System BoardReplace the sideplane. See Installing the Sideplane Board Installing the System BoardSystem Board Jumpers Jumper Setting DescriptionConnector Description System Board ConnectorsSideplane Board Connectors SAS/SATA Backplane Board ConnectorsExpansion-Card Riser-Board Components and PCIe Buses Disabling a Forgotten PasswordOpen the system. See Opening and Closing the System Back to Contents System Setup Options Entering the System Setup ProgramResponding to Error Messages Using the System Setup ProgramUsing the System Password and Using the Setup Password System Setup Program OptionsMemory Information Screen Memory Information ScreenIntegrated Devices Screen CPU Information ScreenCPU Information Screen System Security Screen Serial Communication ScreenIntegrated Devices Screen Options Serial Communication Screen OptionsEnabled System and Setup Password FeaturesDisabled Exit ScreenAssigning a System Password Using the System PasswordDeleting or Changing an Existing System Password Using the Setup PasswordEntering the BMC Setup Module Baseboard Management Controller ConfigurationBMC Setup Module Options See Disabling a Forgotten PasswordTroubleshooting IRQ Assignment Conflicts Safety First-For You and Your SystemStart-Up Routine Checking the EquipmentTroubleshooting the Video Subsystem Troubleshooting External ConnectionsIRQ Assignment Defaults IRQ Line AssignmentTroubleshooting the Keyboard Troubleshooting Basic I/O FunctionsTroubleshooting the Mouse Troubleshooting a USB Device Troubleshooting a Serial I/O DeviceTroubleshooting a Wet System Troubleshooting a NICClose the system. See Opening and Closing the System Troubleshooting the System Battery Troubleshooting a Damaged SystemTroubleshooting System Cooling Problems Troubleshooting Power SuppliesTroubleshooting a Fan Troubleshooting System MemoryTroubleshooting an SD Card or Internal USB Key Troubleshooting an External Tape Drive Troubleshooting an Optical DriveRemove the bezel. See Removing the Front Bezel Troubleshooting a Hard DriveTroubleshooting a SAS Controller Daughter Card Troubleshooting Expansion Cards Troubleshooting the Microprocessors