Hard-Drive Indicator Codes
The
Figure 1-2. Hard-Drive Indicators
1
Table
NOTE: For
Table 1-3. Hard-Drive Indicator Patterns for RAID
Condition |
|
|
|
|
|
Identify drive/preparing for removal | Blinks green two times per second |
|
Drive ready for insertion or removal | Off |
|
|
|
|
Drive predicted failure | Blinks green, amber, and off. |
|
|
|
|
Drive failed | Blinks amber four times per second. |
|
|
|
|
Drive rebuilding | Blinks green slowly. |
|
|
|
|
Drive online | Steady green. |
|
|
|
|
Rebuild aborted | Blinks green three seconds, amber three seconds, and off six seconds. |
|
|
|
|
|
|
|
Back-Panel Features and Indicators
Figure 1-3 shows the controls, indicators, and connectors located on the system's back panel.
Figure 1-3. Back-Panel Features and Indicators
1 | PCIe slot 1 | 2 | PCIe slot 2 |
|
|
|
|
3 | PCIe slot 3 | 4 | PCIe slot 4 |
|
|
|
|
5 | power supply bay 1 (PS1) | 6 | power supply bay 2 (PS2) |
|
|
|
|