Chapter 1 PPI/DGL SETUP Menu
Euro Character
Allows the operator to select the position of the Euro character in the code page.
Control Codes
Allows the operator to change the prefix of the software commands interpreted by the printer.
| S O H | S T X | C R | E S C | ‘C o u n t B y ’ |
S ta n d a rd | 0 x 0 1 | 0 x 0 2 | 0 x 0 D | 0 x 1 B | 0 x 5 E |
A ltern a te | 0 x 5 E | 0 x 7 E | 0 x 0 D | 0 x 1 B | 0 x 4 0 |
A ltern a te 2 | 0 x 5 E | 0 x 7 E | 0 x 7 C | 0 x 1 B | 0 x 4 0 |
U ser | 0 x 0 1 | 0 x 0 2 | 0 x 0 D | 0 x 1 B | 0 x 5 E |
When
Feedback Chars
When enabled, the printer returns a Hex 1E [RS] after each label successfully prints, and Hex 1F [US] after each batch of labels is printed.
For invalid characters, the printer responds with Hex 07 [BEL].
•Enabled. Feedback characters are sent to the host.
•Disabled. No feedback characters are sent.
The default is Disabled.
Default Module
Sets the default module used to store files when no module or default module is specified in the command. (See Chapter 3 for further details.)
.
•RAM.
•Flash.
The default is RAM.
Units of Measure
Sets the printer to interpret measurements as Imperial or Metric values.
•Imperial.
•Metric.
The default is Imperial.
NOTE: <STX>n and <STX>m commands override this setting, and stay in effect until the printer is take Offline and back Online.
14