6.1 - Prefix Settings

If you scan the following codes, you will lose any unsaved settings. Make sure to save settings on your reader before scanning the prefi x codes. If you scan more than one prefi x you will receive each scanned prefi x in your scanned data; (i.e., if you scan comma prefi x twice, you will get two comma prefi xes). Scan the following codes to set appropriate prefi x:

Prefix - Comma

Prefix - Space

Prefix - Tab (USB Mode)

Prefix - Tab

Prefix - Erase

Prefix - Carriage Return Line Feed

 

This code will

Only Use with

 

erase all prefi x

Serial Applications

 

data.

 

Note: If you require a special confi guration, please contact Code at (801) 495-2200.

6.2 - Suffix Settings

If you scan the following codes, you may lose your current settings. Make sure to save settings on your reader before scanning the Suffi x codes. If you scan more than one suffi x you will receive each scanned suffi x in your scanned data; (i.e., if you scan comma suffi x twice, you will get two comma suffi xes). Scan the following codes to set appropriate suffi x:

Suffix - Carriage Return

Suffix - Comma

Suffix - Line Feed

Only Use with

 

Only Use with

Serial Applications

 

Serial Applications

Suffix - Carriage Return Line Feed

Suffix - Space

Suffix - Enter

Only Use with

 

Only Use with

Serial Applications

 

USB or Keyboard

 

 

Mode

Save Settings

C002332_09_CR3 User Manual - 56

Image 62
Contents Manual Version Statement of Agency Compliance Laser/LED RadiationSave Settings Table of Contents CR3 Programming Symbology Settings Reader Feedback and Special SettingsAdvanced Decode Performance Adding a Prefix or Suffix and Reader Text CommandsCR3 Maintenance and Troubleshooting Getting Started Introduction Powering On/Off Reader UnpackingKeypad/Icon Overview Description of Button FunctionPower Icons Icon DescriptionIntroduction RS232 Considerations RS232 Batch Cable-Detect DefaultBatch Operation Cabled Operation IntroductionUSB Cable Installation Guide USB Keyboard ModeReset to USB Factory Defaults USB Communication SettingsUSB Virtual COM 1 Way Mode USB Keyboard USB DownloaderPS2 Mode Save Settings PS2 Cable Installation GuidePS2 Communication Settings Baud Rate RS232 Cable Installation GuideMode RS232 One Way Mode Stop Bits Data Bits Parity NoneRS232 Communication Baud Rate Settings RS232 Communication Data Bit SettingsRS232 Communication Stop Bit Settings RS232 Communication Parity SettingsCabled Reader Time Out Settings Cabled 2 hours Cabled Always DefaultBluetooth Radio Operation Example Reset to RF Factory Defaults QuickConnectRF One Way Mode Max Range RF Two Way ModeBluetooth Radio Auto Connect On Default Bluetooth Radio Auto ConnectBluetooth Disconnect Bluetooth Radio Out of Range Notification Settings Bluetooth Radio Auto DisconnectBluetooth Radio Time Out Settings Uncabled Operations RS232 Bluetooth RadioReader Feedback Guide To read a symbol with the CR3 Targeting and Reading TechniquesImager Field of View and Resolution Decode Zone H1 Handle BH1 or BH2 Battery HandleAttaching Handles Reader Battery Installation Attaching and Detaching the Lithium Ion BatteryOptimization and Trigger Programming Introduction DOTGlobal Trigger Optimization Matrix Left Trigger Programming Read Codes with Both Imagers DefaultLeft Trigger Optimization Matrix Read with Near-Field Imager onlyRead Code with Near-Field Imager only Right Trigger Optimization MatrixRight Trigger Programming Handle Optimization Matrix Handle Trigger ProgrammingContinuous Scan Far Field Only On Off DefaultContinuous Trigger Optimization Both Near & Far Field OnContinuous Scan Trigger Delays Continuous Scan SettingsMotion Detection Scan Settings Continuous Scan Sleep Time OutCR3 Programming Symbology Settings Aztec Symbology Codabar SymbologyCode 39 Symbology Codablock F SymbologyCode 11 Symbology Codablock F On Codablock F Off DefaultCode 93 On Default Code 93 Off Code 93 SymbologyCode 128 Symbology Sample Trioptic CodeGoCode Symbology Composite SymbologiesData Matrix Symbology Interleaved 2 of 5 Symbology Maxicode SymbologyMSI Plessy On MSI Plessy Off Default Sample MSI Plessy Matrix 2 of 5 SymbologyMSI Plessy Symbology NEC 2 of 5 Symbology NEC 2 of 5 On NEC 2 of 5 Off DefaultPharmacode Postal SymbologiesRoyal Mail On Disable All Postal Codes Default Australian Post On Japan Post OnQR Code Symbology RSS SymbologyTelepen Symbology UPC/EAN/JANReader Feedback and Special Settings Code Readability Index Volume and Vibration SettingsOff Default Low Medium Vibrate On / Beep On Vibrate On / Beep OffLow Med Default High Backlight Intensity SettingsReadability Index Output Disable Reader Power Off Settings Backlight Timeout SettingsLaser Settings Reader ID and Firmware Version Reader Settings LockReader Settings Locked Reader ID and FirmwareKeyboard Support Time Stamp SettingsUS English Default US English Leading No Leading French GermanLock-out Link Mode Reader ID Firmware Version Lockout Link ModeAdvanced Decode Performance Continuous Illumination DefaultEnable Continuous Illumination Set Targeting Zone TolerancesWindowing Large 2-Dimensional Codes 640 x 640 pixels Enable VGA 640 x VGA & Megapixel SettingsCodes Enable Sxga 1280 x Mirror DecodingAdding a Prefix or Suffix and Reader Text Commands Prefix Comma Prefix Space Prefix SettingsSuffix Settings Reader Text Commands On Erase Prefix and Suffix SettingsReader Text Commands Erase Prefix & Suffix DataCR3 Maintenance and Troubleshooting Reset Reader to Factory Defaults General Safety InformationTerms of Warranty WarrantyLimited Warranty Warranty Coverage and ProcedureCR3 Accessories GeneralCleaning the CR3 Window Frequently Asked QuestionsCR3 Maintenance Technical Support and Returns