Set Communications Port Command Ka

COMMAND <Ka baud, parity, stop bits, data bits>

Parameter

ASCII

Option

Baud

0

600

 

1

1200

 

2

2400

 

3

4800

 

4

9600 *

 

5

19,200

 

6

38,400

Parity

0

none

 

1

even *

 

2

odd

Stop Bits

0

one *

 

1

two

Data Bits

0

seven *

 

1

eight

Sending the configuration command Ka sets the communications port parameters. Baud rate, parity, stop bits and data bits may be selected. For example, if you wanted to set the baud rate to 2400, the parity to none, the stop bits to two, and the data bits to eight; you would send the following command: <Ka 2, 0, 1, 1>. If you only wanted to set the baud rate to 4800, leaving the other parameters unchanged, you could send the following abbreviated command: <Ka 3>. If you only wanted to set the stop bits to two, leaving the other parameters unchanged, you could send the following command: <Ka , , 1>. The default setting is 9600 baud, even parity, one stop bit, and seven data bits.

Tip: The Ka command does not become effective until the 3700 is reset. Since reset causes the 3700 to use the configuration saved in non–volatile memory, the Ka command should be followed by a Save Configuration command <Z> and a Reset command <A>.

4–6

Configuring the SCANTEAM 3700

Image 32
Contents SCANTEAMR3700 CCD Disclaimer Patents Page Table of Contents Chapter Configuring the Scanteam Technical Specifications Serial Commands SummaryCCD Operation and Bar Code Scanning Ascii Conversion TableList of Tables Overview of the Technical Manual PrefaceIntended Audience Related Publications Scanteam 3700 Hardware Description Scanteam 3700 DescriptionIntroduction Nonvolatile Memory Scanteam 3700 Software DescriptionInterface Port System Hardware Description Basic System OperationGeneral Characteristics Mechanical LayoutSingle Modular Input /Output/Power Port Audible IndicatorOperating Theory Mounting InsertsAsynchronous Serial Ascii Interface Scanner/Host CommunicationCommunications Port Hardwire Pinouts Auxiliary TriggerPower Requirements SET-UP and Installation General Preparation for UsePreparation Set-up Procedure for EvaluationSet-up Checklist Set-up Procedure To setup serial communications to the scannerInstallation in the Host Instrument Top View Examples of Scanteam 3700 Barcode Orientation Pitch or Roll Scanner Illumination Clearance Configuring the Scanteam PreparationData string Command ConventionsCommand Format Operational Commands Reset Command aDisable Decoding Command DC4 Enable Decoding Command DC2Serial Trigger Command Save Configuration Command ZSave Configuration 3C 5A 3E Serial Trigger 3C 31 3EConfiguration Commands Option Set Communications Port Command KaCommand Ka baud, parity, stop bits, data bits Parameter Scanteam 3700 Code ID Values Command Kd enable, data ParameterCode ID Value Definition Set Postamble Command Ke Command Ke enable, data ParameterSet Communications Protocol Command Kf Command Kf mode ParameterSet Read Timeout Command Kh Set Trigger Mode Command KgCommand Kg modeglobal, modeport1, modeport2, # Parameter Set Votes Command Km Set No Read Message Command KkCommand Kk enable, data Parameter Set Code 39 Command Kp Set UPC A/E, EAN 8/13 Command Ks Command Ks enable UPC, enable EAN ParameterSet Scan Rate Command Kv Set Code 128 Command KtSet Beeper Mode Command Ku Configuration Status Query Commands Default Configuration Symbology Settings Default Operating ParametersDefault Configuration Settings SERVICE/TECHNICAL Assistance MaintenanceTroubleshooting Guide Troubleshooting HintsDiagnostic Procedure Troubleshooting ChecklistProblem Possible Cause Solution Scanteam 3700 Troubleshooting ChecklistObtaining Factory Service Product Service DepartmentHelp Desk Service Under WarrantyOut Of Warranty Service Scanteam 3700 Removal/Replacement Followed during installation ChapterService/Technical Assistance Objectives Scanning and Decoding a Bar Code SymbolCCD Operation and BAR Code Scanning a Peak Detectors and Comparator LED ReflectorCCD Sensor Microprocessor Timing SequenceBar Code Scanning Closer Look At Bar Code SymbolsBar Code Basics and Scanning Tips Scanner Performance Technical SpecificationsOptical Specifications MRD minimum reflective difference 37.5% Skew AnglePitch Angle Light Source IlluminationElectrical Specifications Environmental Specifications Mechanical SpecificationsBar Code Symbol Specifications Scanteam 3700 Interface Cable To Host SystemSerial Commands Summary Command FormatCommandFormat Individual Configuration QueryKa? Kd?Symbology Configuration Default Settings Default Configuration SettingsConfiguration CommandDefault Settings Serial Commands Summary Ascii Conversion Table Control Function DefinitionsAscii Conversion Table Scanteam 3700 Glossary Glossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Index Scanteam Index-3 Index-4 Scanteam 3700 Limited Warranty Jordan Road Box Skaneateles Falls, New York 3700/TM Rev E