Hand Held Products 3700 CCD MRD minimum reflective difference 37.5%, Skew Angle, Pitch Angle

Page 54

Focal Distance (selected at time of order) from scanner window:

Focal Distance

Maximum Scan Width

0.6inches [15mm] with a 3 inch [76mm] maximum scan width

1.95inches [50mm] with a 3.5 inch [89mm] maximum scan width

3.2inches [81.3mm] with a 3.5 inch [89mm] maximum scan width

MRD (minimum reflective difference): 37.5%

Tilt Angle:Controlled by bar code length and height (See Figure 3.4)

Skew Angle:

+30 to –30 degrees (See Figure 3.4)

 

Specular reflection zone 0 to –10 degrees

 

(Operation in this zone must be avoided.)

Pitch Angle:

+7 to – 7 degrees on 7.5 mil (See Figure 3.4)

Light Source (Illumination):

Visible Red LED (Wavelength = 645 nm ±30)

CCD Type

Standard Resolution/Standard Performance

 

Standard Resolution/Enhanced Performance

 

High Resolution/Enhanced Performance

B–2

Technical Specifications

Image 54
Contents SCANTEAMR3700 CCD Disclaimer Patents Page Table of Contents Chapter Configuring the Scanteam CCD Operation and Bar Code Scanning Technical SpecificationsSerial Commands Summary Ascii Conversion TableList of Tables Preface Intended AudienceOverview of the Technical Manual Related Publications Scanteam 3700 Description IntroductionScanteam 3700 Hardware Description Scanteam 3700 Software Description Interface PortNonvolatile Memory System Hardware Description Basic System OperationGeneral Characteristics Mechanical LayoutOperating Theory Single Modular Input /Output/Power PortAudible Indicator Mounting InsertsScanner/Host Communication Communications PortAsynchronous Serial Ascii Interface Hardwire Pinouts Auxiliary TriggerPower Requirements SET-UP and Installation General Preparation for UseSet-up Procedure for Evaluation Set-up ChecklistPreparation Set-up Procedure To setup serial communications to the scannerInstallation in the Host Instrument Top View Examples of Scanteam 3700 Barcode Orientation Pitch or Roll Scanner Illumination Clearance Configuring the Scanteam PreparationCommand Conventions Command FormatData string Disable Decoding Command DC4 Operational CommandsReset Command a Enable Decoding Command DC2Save Configuration 3C 5A 3E Serial Trigger CommandSave Configuration Command Z Serial Trigger 3C 31 3EConfiguration Commands Set Communications Port Command Ka Command Ka baud, parity, stop bits, data bits ParameterOption Command Kd enable, data Parameter Code ID Value DefinitionScanteam 3700 Code ID Values Set Postamble Command Ke Command Ke enable, data ParameterSet Communications Protocol Command Kf Command Kf mode ParameterSet Trigger Mode Command Kg Command Kg modeglobal, modeport1, modeport2, # ParameterSet Read Timeout Command Kh Set No Read Message Command Kk Command Kk enable, data ParameterSet Votes Command Km Set Code 39 Command Kp Set UPC A/E, EAN 8/13 Command Ks Command Ks enable UPC, enable EAN ParameterSet Code 128 Command Kt Set Beeper Mode Command KuSet Scan Rate Command Kv Configuration Status Query Commands Default Operating Parameters Default Configuration SettingsDefault Configuration Symbology Settings Troubleshooting Guide SERVICE/TECHNICAL AssistanceMaintenance Troubleshooting HintsProblem Possible Cause Solution Diagnostic ProcedureTroubleshooting Checklist Scanteam 3700 Troubleshooting ChecklistObtaining Factory Service Product Service DepartmentService Under Warranty Out Of Warranty ServiceHelp Desk Scanteam 3700 Removal/Replacement Followed during installation ChapterService/Technical Assistance Scanning and Decoding a Bar Code Symbol CCD Operation and BAR Code Scanning aObjectives LED Reflector CCD SensorPeak Detectors and Comparator Microprocessor Timing SequenceCloser Look At Bar Code Symbols Bar Code Basics and Scanning TipsBar Code Scanning Technical Specifications Optical SpecificationsScanner Performance Pitch Angle MRD minimum reflective difference 37.5%Skew Angle Light Source IlluminationElectrical Specifications Environmental Specifications Mechanical SpecificationsBar Code Symbol Specifications Scanteam 3700 Interface Cable To Host SystemSerial Commands Summary Command FormatKa? CommandFormatIndividual Configuration Query Kd?Default Configuration Settings Configuration CommandDefault SettingsSymbology Configuration Default Settings Serial Commands Summary Ascii Conversion Table Control Function DefinitionsAscii Conversion Table Scanteam 3700 Glossary Glossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Index Scanteam Index-3 Index-4 Scanteam 3700 Limited Warranty Jordan Road Box Skaneateles Falls, New York 3700/TM Rev E