Hand Held Products 3700 CCD manual Environmental Specifications, Mechanical Specifications

Page 56

Indicators:

Beeper.

 

See descriptions below.

Beeper

The good read/no read beeper indicator is configurable and can be disabled, if desired.

B.4 Environmental Specifications

Operating Temperature:

32° F to 122° F (0° C to +50° C)

Storage Temperature:

–40°F to 158° F (–40°C to +70° C)

Relative Operating

 

and Storage Humidity:

0 to 95% (non–condensing)

Barometric Pressure:

101,000 to 69,000 Pascals

 

(Sea level to 3000 meters)

ESD:

15 KV

A drain path for ESD should be provided when installing a 3700 in the host system.

Shock (Drop Test):

Sustains three (3) drops from 4 feet (1.2

 

meters) to a non–yielding surface

Mean Time Between

 

Failure (Ground Benign):

45,000 hrs. minimum

 

(will vary among models)

B.5 Mechanical Specifications

3700:

Width:

3.5 Inches (89mm)

 

Length:

2.9 Inches (75mm)

 

Height:

1.05 Inches (26m)

Interface Cables:

1) Welch Allyn p/n 42204595–01

 

Input/Output cable with 25 pin connector.

Note: A null modem is required for connection to a DTE type port.

Mounting Holes:

Four #6–32 UNC–2B (M3.5)

 

(Alternate dimensions available.)

B–4

Technical Specifications

Image 56
Contents SCANTEAMR3700 CCD Disclaimer Patents Page Table of Contents Chapter Configuring the Scanteam Technical Specifications Serial Commands SummaryCCD Operation and Bar Code Scanning Ascii Conversion TableList of Tables Overview of the Technical Manual PrefaceIntended Audience Related Publications Scanteam 3700 Hardware Description Scanteam 3700 DescriptionIntroduction Nonvolatile Memory Scanteam 3700 Software DescriptionInterface Port System Hardware Description Basic System OperationGeneral Characteristics Mechanical LayoutSingle Modular Input /Output/Power Port Audible IndicatorOperating Theory Mounting InsertsAsynchronous Serial Ascii Interface Scanner/Host CommunicationCommunications Port Hardwire Pinouts Auxiliary TriggerPower Requirements SET-UP and Installation General Preparation for UsePreparation Set-up Procedure for EvaluationSet-up Checklist Set-up Procedure To setup serial communications to the scannerInstallation in the Host Instrument Top View Examples of Scanteam 3700 Barcode Orientation Pitch or Roll Scanner Illumination Clearance Configuring the Scanteam PreparationData string Command ConventionsCommand Format Operational Commands Reset Command aDisable Decoding Command DC4 Enable Decoding Command DC2Serial Trigger Command Save Configuration Command ZSave Configuration 3C 5A 3E Serial Trigger 3C 31 3EConfiguration Commands Option Set Communications Port Command KaCommand Ka baud, parity, stop bits, data bits Parameter Scanteam 3700 Code ID Values Command Kd enable, data ParameterCode ID Value Definition Set Postamble Command Ke Command Ke enable, data ParameterSet Communications Protocol Command Kf Command Kf mode ParameterSet Read Timeout Command Kh Set Trigger Mode Command KgCommand Kg modeglobal, modeport1, modeport2, # Parameter Set Votes Command Km Set No Read Message Command KkCommand Kk enable, data Parameter Set Code 39 Command Kp Set UPC A/E, EAN 8/13 Command Ks Command Ks enable UPC, enable EAN ParameterSet Scan Rate Command Kv Set Code 128 Command KtSet Beeper Mode Command Ku Configuration Status Query Commands Default Configuration Symbology Settings Default Operating ParametersDefault Configuration Settings SERVICE/TECHNICAL Assistance MaintenanceTroubleshooting Guide Troubleshooting HintsDiagnostic Procedure Troubleshooting ChecklistProblem Possible Cause Solution Scanteam 3700 Troubleshooting ChecklistObtaining Factory Service Product Service DepartmentHelp Desk Service Under WarrantyOut Of Warranty Service Scanteam 3700 Removal/Replacement Followed during installation ChapterService/Technical Assistance Objectives Scanning and Decoding a Bar Code SymbolCCD Operation and BAR Code Scanning a Peak Detectors and Comparator LED ReflectorCCD Sensor Microprocessor Timing SequenceBar Code Scanning Closer Look At Bar Code SymbolsBar Code Basics and Scanning Tips Scanner Performance Technical SpecificationsOptical Specifications MRD minimum reflective difference 37.5% Skew AnglePitch Angle Light Source IlluminationElectrical Specifications Environmental Specifications Mechanical SpecificationsBar Code Symbol Specifications Scanteam 3700 Interface Cable To Host SystemSerial Commands Summary Command FormatCommandFormat Individual Configuration QueryKa? Kd?Symbology Configuration Default Settings Default Configuration SettingsConfiguration CommandDefault Settings Serial Commands Summary Ascii Conversion Table Control Function DefinitionsAscii Conversion Table Scanteam 3700 Glossary Glossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Index Scanteam Index-3 Index-4 Scanteam 3700 Limited Warranty Jordan Road Box Skaneateles Falls, New York 3700/TM Rev E