Scan Rate– is the number of times a laser’s scanning beam passes through the exit window in one second.

Scan Velocity– is the speed of a laser’s scanning beam on a target at a given distance from the front of the scanner or rotating polygon mirror. Usually expressed in inches/sec.

Scan Width– is the length of the widest bar code label that can be successfully interpreted by the scanner.

Scanner– is an opto–electronic device which produces electrical signals representing the light it detects as it “sees” a bar code.

SMT– is an acronym for “surface mount technology.”

Specular Reflection Zone – The zone where light from the scanner’s illumination source is reflected directly back into the scanner. Specular reflection interferes with the scanner’s operation. This zone should be avoided.

Start/Stop Characters– are characters used at the beginning and end of a bar code label that indicate the start and stop (end) of the label.

Trigger– is a signal input to the decoder that the scanning process should be initiated. The actual trigger mechanisms can be a push button switch, photoelectric control, internal object sense, proximity sensor, or multiple combinations of all of these.

Usable Scan Length– refers to that portion of the scan path for which the scanner can accurately digitize bar code and maintain all its specifications. This length is specified on a flat surface which is perpendicular to the optical axis of the scanner.

Volatile– refers to the characteristic of a device which loses data in memory when power is lost or turned off.

Voltage Range– refers to the specified range of voltages over which a decoder or a scanner can maintain all of its electrical, optical (for scanners), and environmental specifications.

Voting– is a feature of the SCANTEAM 3700 set by using the Set Votes Configuration Command, Km. If the Voting selection is set to more than 1, the SCANTEAM 3700 decodes and compares consecutive outputs from the scanner(s); successive reads of the same data are required for a valid read. Voting results is a slightly slower read rate, but will reduce the probability of reading errors when a laser scanner, especially, is being used. If the Voting selection is set to 1, only one laser scan resulting in a successful decode is required for a valid read.

Glossary–5

Image 69
Contents SCANTEAMR3700 CCD Disclaimer Patents Page Table of Contents Chapter Configuring the Scanteam Serial Commands Summary Technical SpecificationsCCD Operation and Bar Code Scanning Ascii Conversion TableList of Tables Preface Intended AudienceOverview of the Technical Manual Related Publications Scanteam 3700 Description IntroductionScanteam 3700 Hardware Description Scanteam 3700 Software Description Interface PortNonvolatile Memory Basic System Operation System Hardware DescriptionMechanical Layout General CharacteristicsAudible Indicator Single Modular Input /Output/Power PortOperating Theory Mounting InsertsScanner/Host Communication Communications PortAsynchronous Serial Ascii Interface Auxiliary Trigger Hardwire PinoutsPower Requirements General Preparation for Use SET-UP and InstallationSet-up Procedure for Evaluation Set-up ChecklistPreparation To setup serial communications to the scanner Set-up ProcedureInstallation in the Host Instrument Top View Examples of Scanteam 3700 Barcode Orientation Pitch or Roll Scanner Illumination Clearance Preparation Configuring the ScanteamCommand Conventions Command FormatData string Reset Command a Operational CommandsDisable Decoding Command DC4 Enable Decoding Command DC2Save Configuration Command Z Serial Trigger CommandSave Configuration 3C 5A 3E Serial Trigger 3C 31 3EConfiguration Commands Set Communications Port Command Ka Command Ka baud, parity, stop bits, data bits ParameterOption Command Kd enable, data Parameter Code ID Value DefinitionScanteam 3700 Code ID Values Command Ke enable, data Parameter Set Postamble Command KeCommand Kf mode Parameter Set Communications Protocol Command KfSet Trigger Mode Command Kg Command Kg modeglobal, modeport1, modeport2, # ParameterSet Read Timeout Command Kh Set No Read Message Command Kk Command Kk enable, data ParameterSet Votes Command Km Set Code 39 Command Kp Command Ks enable UPC, enable EAN Parameter Set UPC A/E, EAN 8/13 Command KsSet Code 128 Command Kt Set Beeper Mode Command KuSet Scan Rate Command Kv Configuration Status Query Commands Default Operating Parameters Default Configuration SettingsDefault Configuration Symbology Settings Maintenance SERVICE/TECHNICAL AssistanceTroubleshooting Guide Troubleshooting HintsTroubleshooting Checklist Diagnostic ProcedureProblem Possible Cause Solution Scanteam 3700 Troubleshooting ChecklistProduct Service Department Obtaining Factory ServiceService Under Warranty Out Of Warranty ServiceHelp Desk Followed during installation Chapter Scanteam 3700 Removal/ReplacementService/Technical Assistance Scanning and Decoding a Bar Code Symbol CCD Operation and BAR Code Scanning aObjectives LED Reflector CCD SensorPeak Detectors and Comparator Timing Sequence MicroprocessorCloser Look At Bar Code Symbols Bar Code Basics and Scanning TipsBar Code Scanning Technical Specifications Optical SpecificationsScanner Performance Skew Angle MRD minimum reflective difference 37.5%Pitch Angle Light Source IlluminationElectrical Specifications Mechanical Specifications Environmental SpecificationsBar Code Symbol Specifications To Host System Scanteam 3700 Interface CableCommand Format Serial Commands SummaryIndividual Configuration Query CommandFormatKa? Kd?Default Configuration Settings Configuration CommandDefault SettingsSymbology Configuration Default Settings Serial Commands Summary Control Function Definitions Ascii Conversion TableAscii Conversion Table Scanteam 3700 Glossary Glossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Index Scanteam Index-3 Index-4 Scanteam 3700 Limited Warranty Jordan Road Box Skaneateles Falls, New York 3700/TM Rev E