Set No Read Message Command Kk |
| |
COMMAND <Kk enable, data> |
| |
Parameter | ASCII | Option |
Enable | 0 | no |
| 1 | yes * (NR) |
Data |
| one to seven ASCII characters |
Sending the configuration command Kk sets the no read message. Any ASCII character can be specified except NUL, ACK, NAK, DC1, DC2, DC3, DC4 or DEL. The default setting is NR (no read).
Tip: The No Read Message is not sent for scanner ports that are configured for a continuous trigger mode.
Set Votes Command Km
COMMAND <Km data_global, data_port_1, data_port_2, #>
Parameter ASCII | Option |
Data | one or two ASCII digits |
| range of 1 to 31 * (3, 1) |
Sending the configuration command Km sets the votes. One or two ASCII digits in the range of 1 to 31 determine the number of consecutive identical decodes required for a valid read. A selection of 1 means that no voting will take place. The default setting is Data_port_1, 3 and Data_port_2, 1, which means voting is set to 3 for port 1 and set to 1 for port 2.
Tip: When using the voting feature for additional decode security, a value of three is generally adequate in most applications.
Configuring the SCANTEAM 3700 |