Set Preamble Command Kd |
| |
COMMAND <Kd enable, data> |
| |
Parameter | ASCII | Option |
Enable | 0 | no |
| 1 | yes * (Port ID, Code ID) |
Data |
| one to four ASCII characters |
Sending the configuration command Kd sets the preamble characters. The preamble option may be enabled or disabled; if enabled, up to four preamble characters may be defined. Any ASCII character can be specified except NUL, ACK, NAK, DC1, DC2, DC3, DC4 or DEL. The character SUB should only be used as the first character in a pair, with the second character being either a 1 or a 2. SUB 1 causes the 3700 to include the Port ID in the preamble, while SUB 2 specifies that the Code ID should be included. Table 4.1 lists the Code ID values. The default setting is preamble enabled, Port ID and Code ID characters sent with data strings.
Tip: When character pairs SUB 1 and SUB 2 are specified in the preamble, the SUB characters are not counted toward the maximum number of ASCII characters allowed (four).
Code ID Value | Definition |
|
|
a | Codabar |
b | Code 39 |
e | Interleaved 2 of 5 |
j | Code 128 |
c | UPC |
d | EAN |
SPACE | No code |
|
|
Table 4.1 SCANTEAM 3700 Code ID Values
Configuring the SCANTEAM 3700 |