Hand Held Products 3700 CCD manual Set Code 39 Command Kp

Page 38

Set Code 39 Command Kp

COMMAND <Kp enable, require checksum, send checksum, minimum length, maximum length>

Parameter

ASCII

Option

Enable

0

no

 

1

yes *

Require Checksum

0

no *

 

1

yes

Send Checksum

0

no *

 

1

yes

Minimum Length

 

Set from 1 to 48 * (1)

Maximum Length

 

Set from 1 to 48 * (48)

Sending the configuration command Kp sets Code 39 and all its parameters: enable/disable, require checksum, send checksum, minimum length, and maximum length. The default setting is Code 39 enabled, doesn’t require or send checksum, minimum length 1, and maximum length 48.

Set Codabar Command Kq

COMMAND <Kq enable, send start/stop, minimum length, maximum length>

Parameter

ASCII

Option

Enable

0

no

 

1

yes *

Send Start/Stop

0

no

 

1

yes *

Minimum Length

 

Set from 1 to 60 * (6)

Maximum Length

 

Set from 1 to 60 * (60)

Sending the configuration command Kq sets Codabar and all its parameters: enable/disable, send start/stop, minimum length, and maximum length. The default setting is Codabar enabled, send start/stop, minimum length 6, and maximum length 60.

4–12

Configuring the SCANTEAM 3700

Image 38
Contents SCANTEAMR3700 CCD Disclaimer Patents Page Table of Contents Chapter Configuring the Scanteam CCD Operation and Bar Code Scanning Technical SpecificationsSerial Commands Summary Ascii Conversion TableList of Tables Overview of the Technical Manual PrefaceIntended Audience Related Publications Scanteam 3700 Hardware Description Scanteam 3700 DescriptionIntroduction Nonvolatile Memory Scanteam 3700 Software DescriptionInterface Port System Hardware Description Basic System OperationGeneral Characteristics Mechanical LayoutOperating Theory Single Modular Input /Output/Power PortAudible Indicator Mounting InsertsAsynchronous Serial Ascii Interface Scanner/Host CommunicationCommunications Port Hardwire Pinouts Auxiliary TriggerPower Requirements SET-UP and Installation General Preparation for UsePreparation Set-up Procedure for EvaluationSet-up Checklist Set-up Procedure To setup serial communications to the scannerInstallation in the Host Instrument Top View Examples of Scanteam 3700 Barcode Orientation Pitch or Roll Scanner Illumination Clearance Configuring the Scanteam PreparationData string Command ConventionsCommand Format Disable Decoding Command DC4 Operational CommandsReset Command a Enable Decoding Command DC2Save Configuration 3C 5A 3E Serial Trigger CommandSave Configuration Command Z Serial Trigger 3C 31 3EConfiguration Commands Option Set Communications Port Command KaCommand Ka baud, parity, stop bits, data bits Parameter Scanteam 3700 Code ID Values Command Kd enable, data ParameterCode ID Value Definition Set Postamble Command Ke Command Ke enable, data ParameterSet Communications Protocol Command Kf Command Kf mode ParameterSet Read Timeout Command Kh Set Trigger Mode Command KgCommand Kg modeglobal, modeport1, modeport2, # Parameter Set Votes Command Km Set No Read Message Command KkCommand Kk enable, data Parameter Set Code 39 Command Kp Set UPC A/E, EAN 8/13 Command Ks Command Ks enable UPC, enable EAN ParameterSet Scan Rate Command Kv Set Code 128 Command KtSet Beeper Mode Command Ku Configuration Status Query Commands Default Configuration Symbology Settings Default Operating ParametersDefault Configuration Settings Troubleshooting Guide SERVICE/TECHNICAL AssistanceMaintenance Troubleshooting HintsProblem Possible Cause Solution Diagnostic ProcedureTroubleshooting Checklist Scanteam 3700 Troubleshooting ChecklistObtaining Factory Service Product Service DepartmentHelp Desk Service Under WarrantyOut Of Warranty Service Scanteam 3700 Removal/Replacement Followed during installation ChapterService/Technical Assistance Objectives Scanning and Decoding a Bar Code SymbolCCD Operation and BAR Code Scanning a Peak Detectors and Comparator LED ReflectorCCD Sensor Microprocessor Timing SequenceBar Code Scanning Closer Look At Bar Code SymbolsBar Code Basics and Scanning Tips Scanner Performance Technical SpecificationsOptical Specifications Pitch Angle MRD minimum reflective difference 37.5%Skew Angle Light Source IlluminationElectrical Specifications Environmental Specifications Mechanical SpecificationsBar Code Symbol Specifications Scanteam 3700 Interface Cable To Host SystemSerial Commands Summary Command FormatKa? CommandFormatIndividual Configuration Query Kd?Symbology Configuration Default Settings Default Configuration SettingsConfiguration CommandDefault Settings Serial Commands Summary Ascii Conversion Table Control Function DefinitionsAscii Conversion Table Scanteam 3700 Glossary Glossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Index Scanteam Index-3 Index-4 Scanteam 3700 Limited Warranty Jordan Road Box Skaneateles Falls, New York 3700/TM Rev E