Serial Communication, cont’d

The syntax for setting a special function is __ * X? # where __ is the function number and X? is the value. To view a function’s setting, use __#, where __ is the function number. In the following table the values of the X? variable are different for each command/function. These values are given in the rightmost column.

Command/response table for special function SIS commands

Command

ASCII Command

Response

 

values

X?

 

(host to switcher)

(switcher to host)

and additional descriptions

 

 

 

 

 

Delay times

Power on delay

1 *

X?

#

WarmUp*

X?

0 = 0 seconds,

 

 

 

 

1 = 2 seconds,

 

 

 

 

2 = 4 seconds,

 

 

 

 

... in 2 second steps up to

 

 

 

 

150 = 300 seconds (5 minutes).

Example:

1*8#

WarmUp*08

Example: set a 16 second power on delay

Example:

1#

WarmUp*023

Example: view the power on delay

 

 

 

setting.

Power off delay

2 *

X?

#

CoolDown*

X?

0

= 0 seconds,

 

 

 

 

1

= 2 seconds,

 

 

 

 

2

= 4 seconds,... in 2 second

steps up to 150 = 300 seconds.

Example:

2*23#

CoolDown*023

Example: set a 46 second power off

delay.

RGB delay (Triple-Action Switching)

3 *

X?

#

RGBDly*

X?

0 = 0.0 seconds (default), 1 = 0.5

 

 

 

 

seconds, 2 = 1.0 seconds,

 

 

 

 

... in ½ second steps up to

 

 

 

 

10 = 5.0 seconds

Example:

3*7#

RGBDly*07

Example: 3.5 second RGB delay

Room relays

Room relay 1 mode/timing

4 *

X?

#

Rly1Tm*

X?

0 = toggle mode (press on/off),

 

 

 

 

1

= momentary, 1/8 second long,

 

 

 

 

2

= momentary, ¼ second long,

 

 

 

 

3

= momentary, 3/8 second long,

 

 

 

 

... in 1/8 second steps up to

 

 

 

 

16 = 2.0 seconds

Example:

4*15#

 

Rly1Tm*15

Example: momentary, 1.875 sec. long

Room relay 2 mode/timing

5 *

 

#

Rly2Tm*

 

0 = toggle mode (press on/off),

X?

X?

 

 

 

 

 

 

1

= momentary, 1/8 second long,

 

 

 

 

 

 

2

= momentary, ¼ second long,

 

 

 

 

 

 

3

= momentary, 3/8 second long,

 

 

 

 

 

 

... in 1/8 second steps up to

 

 

 

 

 

 

16 = 2.0 seconds

Example:

5*8#

 

Rly2Tm*08

Example: momentary, 1.0 sec. long

Scaler settings

Scaler output sync format

6 *

X?

#

SyncOut*

X?

0

= RGBHV (default)

 

 

 

 

1

= RGBS

 

 

 

 

2

= RGsB (sync on green, SOG)

Example:

6*1#

 

 

SyncOut*1

Example: RGBHV sync output

Scaler output polarity

7 *

 

 

 

#

SyncPol*

 

0

= H-/V- (default)

X?

X?

 

 

 

 

 

 

 

 

 

 

1

= H-/V+

 

 

 

 

 

 

 

 

 

 

2

= H+/V-

 

 

 

 

 

 

 

 

 

 

3

= H+/V+

Example:

7*1#

 

 

SyncPol*1

Example: H-/V+ sync polarity

 

 

 

 

 

 

 

 

 

 

 

 

Blue screen (blue & sync output only)

8*

 

#

Blu*

 

 

0

= off (default) (RGB & sync output)

X?

X?

 

 

 

 

 

 

 

 

 

 

1 = on (blue video & sync output only)

Example:

8*1#

 

 

Blu*1

Example: blue & sync output for setup

 

 

 

 

 

 

 

 

 

 

 

 

4-8 System 7SC • Serial Communication

Page 56
Image 56