Command/response table for SIS commands (continued)

Command

ASCII Command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

Executive mode (front panel lockout)

 

 

 

 

 

 

 

 

 

 

Disable

0X

Exe0

Adjustments & selections can

 

 

 

 

 

be made from the front panel.

Enable (lock image adjustments)

1X

Exe1

Lock front panel adjustments;

 

 

 

 

 

adjust image via RS-232 only.

Enable (lock selection & adjustments)

2X

Exe2

Lock all front panel controls

 

 

 

 

 

(adjustments & input selection);

 

 

 

 

 

adjust via RS-232 only, select via

 

 

 

 

 

RS-232 or IR 701.

View the executive mode status

X

Exe

 

 

Show executive mode status.

X16

Example:

X

Exe0

 

Firmware version, part number & information requests

Query firmware version number

Q

Ver

X8

Show the controller firmware version.

Request part number

N

N60-340-01

Show the switcher’s part #.

Request general info.

I

(See below.)

Show the switcher’s status.

 

 

Vid

X1

•Aud

X1

•Std

X12

•Max

X5

 

Request projector configuration

K

(16 char + spc + 16 char)

Show which projector driver is

 

 

 

 

 

 

 

 

being used. The response is a

 

 

 

 

 

 

 

 

string of 16 characters + space +

 

 

 

 

 

 

 

 

16 characters (total = 33

 

 

 

 

 

 

 

 

characters).

Example:

K

Proxima_XXXXXXXX•YYYYYYYYYYYYYYYY

Zap (reset to default settings)

Zap audio levels to 0 dB

Zap image adjustments/controls

Esc

zA

ZapA

Reset all audio levels to 0dB.

 

zI

ZapI

Reset the image adjustments to

Esc

 

 

 

factory settings.

Zap user learned IR drivers

Zap Extron downloaded drivers

Zap all System 7 settings/memories

Esc

zU

ZapU

Clear memory page 1 (remove

 

 

 

learned IR drivers).

 

zE

ZapE

Clear memory page 0 (remove

Esc

 

 

 

RS-232/IR projector drivers that

 

 

 

were created by Extron and

 

 

 

downloaded to the System 7

 

 

 

and remove user-entered RS-232

 

 

 

commands).

 

zXXX

ZapXXX

Reset everything: all settings,

Esc

 

 

 

adjustments, and drivers to the

 

 

 

factory default.

System 7SC • Serial Communication

4-7