Installation, cont’d

Control device connections

Captive screw and 3.5 mm stereo jack connectors are included with the switcher, but the installer provides the cables.

OUTPUTS

RH/HV

R-Y

G/Y

V

VID

 

5

B/C

B-Y

SCP/AAP CONTROL

E D C B A E D C B A

12

R

H/HV

 

 

R

R-Y

 

 

 

 

 

G/Y

 

V

 

 

 

 

VID

 

 

 

 

 

 

6

 

 

 

 

 

 

B/C

 

 

 

 

 

 

B-Y

 

 

 

 

 

 

1

2

3

4

5

6

7

CONTACT CLOSURE

G

B

H/HV

V

7

RGB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232

A B C D E A B C D E

 

 

 

E D C B A A B C D E F G H I J

 

 

 

 

 

 

 

 

 

 

 

 

 

DISPLAY PWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY 1

 

 

RELAY 2

 

 

IR COMM

 

 

 

PROJ CONTROL

 

 

 

 

SENSOR

 

 

 

 

 

1

2

3

4

5

6

1SCP/AAP Control ports — Connect Extron SCP control pads (SCP 250,

SCP 200, or SCP/AAP A) to these 5-pole captive screw connectors to provide remote control of the System 7SC. The SCPs replicate several of the front panel controls. The SCP 200 and SCP 250 are also able to receive infrared signals from the IR 701 remote control and send them to the switcher.

In total, up to sixteen (16) control pads in any combination can connected to these ports if they are linked together with cables such as Extron’s Comm Link cable. Refer to the appropriate SCP user’s manual for details and wiring diagrams.

The SCP/AAP Control port has the following pin assignments:

SCP/AAP CONTROL

E D C B A E D C B A

1

2

A

 

 

To / from

B

Ground (shield/drain)

 

 

SCP 200,

C

Comm. signal (white)

 

SCP 250,

D

Ground (black)

 

 

or SCP/AAP A

E

+12 VDC (red)

 

 

 

Each port provides up to 12 VDC for powering the SCP control pads or other devices. However, the total load for both ports combined must not exceed

1 ampere.

The load (such as an SCP control pad or interface) should not be placed further than a maximum of 300 feet (91.4 meters) from the System 7SC switcher.

2Contact closure — Connect an optional contact closure control device here. Select an input channel by making contact closure between an input’s pin (pins 1 through 7 correspond to inputs 1 through 7) and a ground pin (pins 8, 9, and 10). Continuous connections made by contact closure override all other means of selection: continuous contact closure takes precedence over front panel and RS-232 selection.

2-8 System 7SC • Installation

Page 20
Image 20
Extron electronic System 7SC manual Control device connections, Rgb