Hand Held Products 3700 CCD manual Set Postamble Command Ke, Command Ke enable, data Parameter

Page 34

Set Postamble Command Ke

 

COMMAND <Ke enable, data>

 

Parameter

ASCII

Option

Enable

0

no

 

1

yes * (CR, LF)

Data

 

one to four ASCII characters

Sending the configuration command Ke sets the postamble characters. The postamble option may be enabled or disabled; if enabled, up to four postamble characters may be defined. Any ASCII character can be specified except NUL, ACK, NAK, DC1, DC2, DC3, DC4 or DEL. The character SUB should only be used as the first character in a pair, with the second character being either a 1 or a 2. SUB 1 causes the 3700 to include the Port ID in the postamble, while SUB 2 specifies that the Code ID should be included. Port ID is always 1. Table 4.1 lists the Code ID values. The default setting is postamble enabled, CR and LF characters sent with data strings.

Tip: When character pairs SUB 1 and SUB 2 are specified in the postamble, the SUB characters are not counted toward the maximum number of ASCII characters allowed (four).

4–8

Configuring the SCANTEAM 3700

Image 34
Contents SCANTEAMR3700 CCD Disclaimer Patents Page Table of Contents Chapter Configuring the Scanteam CCD Operation and Bar Code Scanning Technical SpecificationsSerial Commands Summary Ascii Conversion TableList of Tables Intended Audience PrefaceOverview of the Technical Manual Related Publications Introduction Scanteam 3700 DescriptionScanteam 3700 Hardware Description Interface Port Scanteam 3700 Software DescriptionNonvolatile Memory System Hardware Description Basic System OperationGeneral Characteristics Mechanical LayoutOperating Theory Single Modular Input /Output/Power PortAudible Indicator Mounting InsertsCommunications Port Scanner/Host CommunicationAsynchronous Serial Ascii Interface Hardwire Pinouts Auxiliary TriggerPower Requirements SET-UP and Installation General Preparation for UseSet-up Checklist Set-up Procedure for EvaluationPreparation Set-up Procedure To setup serial communications to the scannerInstallation in the Host Instrument Top View Examples of Scanteam 3700 Barcode Orientation Pitch or Roll Scanner Illumination Clearance Configuring the Scanteam PreparationCommand Format Command ConventionsData string Disable Decoding Command DC4 Operational CommandsReset Command a Enable Decoding Command DC2Save Configuration 3C 5A 3E Serial Trigger CommandSave Configuration Command Z Serial Trigger 3C 31 3EConfiguration Commands Command Ka baud, parity, stop bits, data bits Parameter Set Communications Port Command KaOption Code ID Value Definition Command Kd enable, data ParameterScanteam 3700 Code ID Values Set Postamble Command Ke Command Ke enable, data ParameterSet Communications Protocol Command Kf Command Kf mode ParameterCommand Kg modeglobal, modeport1, modeport2, # Parameter Set Trigger Mode Command KgSet Read Timeout Command Kh Command Kk enable, data Parameter Set No Read Message Command KkSet Votes Command Km Set Code 39 Command Kp Set UPC A/E, EAN 8/13 Command Ks Command Ks enable UPC, enable EAN ParameterSet Beeper Mode Command Ku Set Code 128 Command KtSet Scan Rate Command Kv Configuration Status Query Commands Default Configuration Settings Default Operating ParametersDefault Configuration Symbology Settings Troubleshooting Guide SERVICE/TECHNICAL AssistanceMaintenance Troubleshooting HintsProblem Possible Cause Solution Diagnostic ProcedureTroubleshooting Checklist Scanteam 3700 Troubleshooting ChecklistObtaining Factory Service Product Service DepartmentOut Of Warranty Service Service Under WarrantyHelp Desk Scanteam 3700 Removal/Replacement Followed during installation ChapterService/Technical Assistance CCD Operation and BAR Code Scanning a Scanning and Decoding a Bar Code SymbolObjectives CCD Sensor LED ReflectorPeak Detectors and Comparator Microprocessor Timing SequenceBar Code Basics and Scanning Tips Closer Look At Bar Code SymbolsBar Code Scanning Optical Specifications Technical SpecificationsScanner Performance Pitch Angle MRD minimum reflective difference 37.5%Skew Angle Light Source IlluminationElectrical Specifications Environmental Specifications Mechanical SpecificationsBar Code Symbol Specifications Scanteam 3700 Interface Cable To Host SystemSerial Commands Summary Command FormatKa? CommandFormatIndividual Configuration Query Kd?Configuration CommandDefault Settings Default Configuration SettingsSymbology Configuration Default Settings Serial Commands Summary Ascii Conversion Table Control Function DefinitionsAscii Conversion Table Scanteam 3700 Glossary Glossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Index Scanteam Index-3 Index-4 Scanteam 3700 Limited Warranty Jordan Road Box Skaneateles Falls, New York 3700/TM Rev E