Hand Held Products 3700 CCD manual Set-up Procedure, To setup serial communications to the scanner

Page 21

3.3.2Set–up Procedure

This procedure will verify that bar code scanning and communications between the host and the 3700 has been established.

To setup serial communications to the scanner

1)Connect the RS–232 communications (I/O) cable between the 3700 and the PC serial port. (You may require a 25 pin to 9 pin converter and Null Modem adapter. Contact your Hand Held Products sales representative or distributor for assistance.)

2)Connect power to the 3700. The scanner should beep once.

3)Start serial communications software program, such as PCTools Desktop (Central Point Software), on the PC.

4)On the PC, set up the serial communications program to match the 3700 default values:

Baud rate = 9600

Parity = Even

Stop Bits = One

Data Bits = Seven

5)The default factory scanner configuration for the SCANTEAM 3700 requires a serial command from a host to trigger a scan. Change the trigger mode to “Continuous Read, Send Once, Clear on Timeout” by typing <Kg , 1>. The elapsed time between the typing of each character should not exceed 5 seconds. The illumination LEDs should light in response to the command.

6)Confirm communications to the 3700 with the test label below. Observe that the LED reflector is illuminated. Scan the test label“ABC123” below. The default scanner configuration for preamble is Port ID and Code ID. Default postamble is CR (carriage return) and LF (line feed). Observe within 3 seconds the message “1bABC123” on the PC.

“1” = Port ID

“b ” = Code ID (Code 39 code ID is “b”)

“ABC123” = The bar code label

A B C 1 2 3

This completes set–up of the SCANTEAM 3700 Machine Mount CCD for evaluation. You are now ready to configure the 3700 to explore the functions and features. Instructions for configuring the 3700 using configuration and operational commands are provided in Chapter 4, Configuring the SCANTEAM 3700.

Set–Up and Installation

3–3

Image 21
Contents SCANTEAMR3700 CCD Disclaimer Patents Page Table of Contents Chapter Configuring the Scanteam Serial Commands Summary Technical SpecificationsCCD Operation and Bar Code Scanning Ascii Conversion TableList of Tables Preface Intended AudienceOverview of the Technical Manual Related Publications Scanteam 3700 Description IntroductionScanteam 3700 Hardware Description Scanteam 3700 Software Description Interface PortNonvolatile Memory Basic System Operation System Hardware DescriptionMechanical Layout General CharacteristicsAudible Indicator Single Modular Input /Output/Power PortOperating Theory Mounting InsertsScanner/Host Communication Communications PortAsynchronous Serial Ascii Interface Auxiliary Trigger Hardwire PinoutsPower Requirements General Preparation for Use SET-UP and InstallationSet-up Procedure for Evaluation Set-up ChecklistPreparation To setup serial communications to the scanner Set-up ProcedureInstallation in the Host Instrument Top View Examples of Scanteam 3700 Barcode Orientation Pitch or Roll Scanner Illumination Clearance Preparation Configuring the ScanteamCommand Conventions Command FormatData string Reset Command a Operational CommandsDisable Decoding Command DC4 Enable Decoding Command DC2Save Configuration Command Z Serial Trigger CommandSave Configuration 3C 5A 3E Serial Trigger 3C 31 3EConfiguration Commands Set Communications Port Command Ka Command Ka baud, parity, stop bits, data bits ParameterOption Command Kd enable, data Parameter Code ID Value DefinitionScanteam 3700 Code ID Values Command Ke enable, data Parameter Set Postamble Command KeCommand Kf mode Parameter Set Communications Protocol Command KfSet Trigger Mode Command Kg Command Kg modeglobal, modeport1, modeport2, # ParameterSet Read Timeout Command Kh Set No Read Message Command Kk Command Kk enable, data ParameterSet Votes Command Km Set Code 39 Command Kp Command Ks enable UPC, enable EAN Parameter Set UPC A/E, EAN 8/13 Command KsSet Code 128 Command Kt Set Beeper Mode Command KuSet Scan Rate Command Kv Configuration Status Query Commands Default Operating Parameters Default Configuration SettingsDefault Configuration Symbology Settings Maintenance SERVICE/TECHNICAL AssistanceTroubleshooting Guide Troubleshooting HintsTroubleshooting Checklist Diagnostic ProcedureProblem Possible Cause Solution Scanteam 3700 Troubleshooting ChecklistProduct Service Department Obtaining Factory ServiceService Under Warranty Out Of Warranty ServiceHelp Desk Followed during installation Chapter Scanteam 3700 Removal/ReplacementService/Technical Assistance Scanning and Decoding a Bar Code Symbol CCD Operation and BAR Code Scanning aObjectives LED Reflector CCD SensorPeak Detectors and Comparator Timing Sequence MicroprocessorCloser Look At Bar Code Symbols Bar Code Basics and Scanning TipsBar Code Scanning Technical Specifications Optical SpecificationsScanner Performance Skew Angle MRD minimum reflective difference 37.5%Pitch Angle Light Source IlluminationElectrical Specifications Mechanical Specifications Environmental SpecificationsBar Code Symbol Specifications To Host System Scanteam 3700 Interface CableCommand Format Serial Commands SummaryIndividual Configuration Query CommandFormatKa? Kd?Default Configuration Settings Configuration CommandDefault SettingsSymbology Configuration Default Settings Serial Commands Summary Control Function Definitions Ascii Conversion TableAscii Conversion Table Scanteam 3700 Glossary Glossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Index Scanteam Index-3 Index-4 Scanteam 3700 Limited Warranty Jordan Road Box Skaneateles Falls, New York 3700/TM Rev E