Minuteman UPS SNMP-32 Series user manual Current Probe Sensor CPS, CPS Status Fig, Threshold

Page 32

7-3. Current Probe Sensor (CPS)

This section will guide you through the SNMP-32 card’s CPS Web pages. See the CPS User’s Manual for installation instruction.

1.CPS Status (Fig. 48)

This screen shows the electrical current detected by CPS and indicates if the current is out of the preset range.

Fig. 48-CPS Status Screen

2.CPS Configuration (Fig. 49)

Name

The user can rename the CPS.

Threshold 1

The user can set the out-of-tolerance value for the first phase.

Threshold 2

The user can set the out-of-tolerance value for the second phase.

Fig. 49-CPS Configuration Screen

32

Image 32
Contents SNMP-32 Series Table of Contents Trademarks Conventions used in this guideFeatures IntroductionPackage Contents Applications External SNMP-32 card SNMP-32L Only Installation ProcedureInternal SNMP-32 card Setup-Procedure Snmp Utility GroupSnmp Utility Set IP address for SNMP-32 card Web Management Interface Main MenuConfiguration Network Information System StatusConfiguration Snmp Access ControlSecondary DNS Server IP Ethernet Connection TypeTrap Notification Snmp ScreenConfiguration Email Email SettingRecipient’s Email Address for Event Log Recipient’s Email Address for Daily ReportUser Account Configuration PPPConfiguration Web/Telnet Configuration System Time Log Information EventATS Event List ENV Event ListCPS Event List Log Information Data Data LogFirmware Upgrade Procedure Snmp Utility Download Firmware Telnet Configuration TelnetSet Snmp Access Control Reset Configuration to DefaultSave & Reboot Set Snmp MIB SystemUninterruptible Power Supply UPS Battery InformationConnected Device UPS InformationBattery Status UPS StatusInput Status Output StatusQuick Battery Test Deep Battery CalibrationCancel Test Shutdown UPS Battery mode onlyGraphic View Graphic View ScreenUPS Settings UPS PropertiesUPS Recorded Test UPSNew Schedule Event Screen RPM Action Remote Power Manager RPM RPM Setting Fig Select RPM Power off DelayPower Resume Delay Address ChangeRPM Schedule RPM Schedule ScreenThreshold Current Probe Sensor CPSCPS Status Fig Temp/Hum32-Probe ENV ENV Status FigAutomatic Transfer Switch ATS Input Power Source aInput Power Source B ATS Status FigConfiguring the NMS General Network Management StationsAppendix CommunitiesGateways IP AddressesSubnet Mask Routing and Filtering Troubleshooting ProblemInstallation Site What are the symptoms?Obtaining Technical Assistance If you are a consultantLimited Product Warranty Limited Product Warranty