8. Configuring the NMS

To complete the SNMP-32 card installation and configuration process, you must compile the necessary MIBs to configure the NMS.

Most NMS with a MIB compiler can manage the SNMP-32 card. For instructions on how to compile MIBs for the most popular NMS—HP OpenView Network Node Manager and SunConnect SunNet Manager, see the corresponding heading below.

General Network Management Stations

Follow these general procedures to configure an NMS:

1.Compile the device MIBs.

2.Add the SNMP-32 card object to the Management Map.

3.Ping the SNMP-32 card.

HP OpenView Network Node Manager for HP-UX

Compile the Device MIB

1.Copy the UPS MIB file from the TAR formatted diskette into the subdirectory /usr/OV/snmp_mibs.

2.From the main menu, select Options

3.Load/Unload MIBs: SNMP...

4.Select Load.

5.Select the MIB file copied earlier.

6.Select OK.

Add the SNMP-32 card Object to the Management Map

1.Select the submap then Edit: Add Object.

2.Select the group computer.

3.With the middle (or opposite) mouse button, drag the generic symbol subclass device to the submap.

4.Enter a name for the object in the Selection and Label fields of the Add Object box.

5.Highlight IP Map from Object Attributes group.

6.Select Set Object Attributes button.

7.Enter Host name and IP address of SNMP-32 card adapter.

8.Enter OK.

9.Enter OK at Add Object menu.

10.Enter OK at Add Object:palette.

Poll the Device OIDs

1.From the main menu, select Monitor: MIB values then Browse MIB: SNMP.

2.Move around the MIBs to view the UPS device information.

Set the Device OIDs

1.From the main menu, select Monitor: MIB values then Browse MIB: SNMP.

2.Select a MIB variable you want to alter by clicking on it.

3.Enter the new value then click on Set.

4.Click on Start Query to view the changes.

Ping the SNMP-32 card

1.Change active Window to Shell.

2.Type ping <IP address> and press <enter>.

35

Image 35
Contents SNMP-32 Series Table of Contents Conventions used in this guide TrademarksIntroduction FeaturesPackage Contents Applications External SNMP-32 card SNMP-32L Only Installation ProcedureInternal SNMP-32 card Snmp Utility Group Setup-ProcedureSnmp Utility Set IP address for SNMP-32 card Main Menu Web Management InterfaceInformation System Status Configuration NetworkEthernet Connection Type Configuration SnmpAccess Control Secondary DNS Server IPSnmp Screen Trap NotificationRecipient’s Email Address for Daily Report Configuration EmailEmail Setting Recipient’s Email Address for Event LogUser Account Configuration PPPConfiguration Web/Telnet Log Information Event Configuration System TimeATS Event List ENV Event ListCPS Event List Data Log Log Information DataFirmware Upgrade Procedure Snmp Utility Download Firmware Telnet Telnet ConfigurationSet Snmp MIB System Set Snmp Access ControlReset Configuration to Default Save & RebootUPS Information Uninterruptible Power Supply UPSBattery Information Connected DeviceOutput Status Battery StatusUPS Status Input StatusShutdown UPS Battery mode only Quick Battery TestDeep Battery Calibration Cancel TestGraphic View Screen Graphic ViewTest UPS UPS SettingsUPS Properties UPS RecordedNew Schedule Event Screen RPM Action Remote Power Manager RPM Address Change RPM Setting Fig Select RPMPower off Delay Power Resume DelayRPM Schedule Screen RPM ScheduleThreshold Current Probe Sensor CPSCPS Status Fig ENV Status Fig Temp/Hum32-Probe ENVATS Status Fig Automatic Transfer Switch ATSInput Power Source a Input Power Source BGeneral Network Management Stations Configuring the NMSIP Addresses AppendixCommunities GatewaysSubnet Mask Routing and Filtering Problem TroubleshootingIf you are a consultant Installation SiteWhat are the symptoms? Obtaining Technical AssistanceLimited Product Warranty Limited Product Warranty