Installation & Operating Instructions
Owner’s Reference PowerPack 1500 MKII
2.6Operating Parameter Setting
2.6.1Configuration
Mode
2.6.2Display and
Control Switch
2.6.3End of
Configuration mode
Restore electrical power to connected equipment by
Press and hold both the main on switch “I” and the main off switch “” on the front panel for more than 3 seconds while the UPS is in the off status. The UPS will now enter parameter configuration mode.
Level Indicator
Status Indicator
•When the UPS enters into the configuration mode, the turn on of six different status indicator LEDs represent different parameter being programmed.
•Different parameter can be selected by pressing and holding the main off switch “” for more than 3 seconds.
•Different settings can be selected by pressing and holding the main on switch
“I” for more than 3 seconds.
• To Exit the configuration mode:
Press and hold both the main on switch “I” and off switch “” for more than 3 seconds.
4826 Sterling Drive, Boulder, CO 80301 |
|
PH: 720.406.8946 service@psaudio.com www.psaudio.com | Getting Started 11 |