Solid State Logic X-Logic Series owner manual AWS Remote Mode, Rack Installation and Operation

Page 13

X-Rack Installation and Operation

4.2.4Copy/Swap

While displaying a TR setup pressing and holding a module SEL switch and then pressing a second SEL switch will swap the setting of the two channels.

Selecting COPY/DEL and then doing the same will copy& settings from the first channel to the second.

Note that Copy/S wap is on ly allowed between similar

modules; t he uni t will n ot allow you to swap set tings COPY/

between an EQ m odule an d a Dyna mics module for DEL instance!

4.2.5 Deleting Stores

stores before a SysEx dump) by

Stores can be cleared (to remove unwanted

holding do wn COPY/DEL till it’s LED

flashes an d pres sing the D-Pot

switch (while still holding down the

COPY/DEL switch). Additional stores

can be de leted by holding dow n the

COPY/DEL switch, selecting th e

second store with the D-Pot and pressing the D-Pot again.

4.2.6Delete All

All st ores ca n be cl eared by holdin g dow n al l three switches unti l their LED s flash, th en pressing the D -Pot switch.

SAVE COPY/

DEL

SEL

SEL

COPY/

DEL

SETUP/

MIDI

+

+

+

+

SEL

SEL

Push to Select

Push to Select

4.3 AWS Remote Mode

4.3.1 System Requirements

The X -RackTOTAL RECALL LINK IN ’ conn ector must be connected to AWS 900 serial port 1 – see Section 3.3 for more details.

If more than one X-Rack is connected each X-Rack must have a different address – refer to the Setup/MIDI Section.

The AWS900 must be running V1.2/6 or higher software and have Total Recall enabled for this to function. This software can be downloaded from the SSL website.

4.3.2Operation

Pressing the Total Recall STORE switch on the AWS 900 will send a message to all attached X-Racks asking for the current control settings to be returned. The returned settings are appended to th e AWS 900 Total Recall stores and are automatically archived and restored as part of the AWS 900 Total Recall system.

Similarly pressing SELECT in the AWS TR page will return the

selected Total Recall set up to th e X-Rack unit (s). The remote load command will always replace the current setup and the X-

Rack display will read ‘re’. To display the new s ettings, press the D-Pot as in ‘Standalon e’ mode an d to exit display mode press the D-Pot a second t ime. If the AWS 900 store does not contain valid data (for example if it was s aved on an AWS 900 not connected to an X-Rack) the ‘Empty’ LED will light and it will not be possible to select display mode.

Settings can be saved to the local stores and recalled at any time by turning the D-Pot (though see the Remote option in the Setup menu section). Pressing STORE in the TR page on the AWS 900 will always save the current state of the unit and pressing SELECT will replace the store to be displayed with the store from the AWS 900.

See the Remote and the Address options in the Setup/MIDI Section. SELECT

Page 9

Image 13
Contents Page Page U N D V I S I O N Solid State LogicSolid State Logic Contents XLogic Warranty Repairs WarrantyOut of Warranty Repairs IntroductionElectrical Safety Warning Safety considerationsInstallation DefinitionsSafety Considerations Graphical SymbolsMains Supply and Phases Mains Isolation and Over-Current ProtectionAssembling the X-Rack Rack InstallationMounting Connection Exiting Display Mode Stand-alone ModeOperation Total Recall Saving Stores to Internal MemoryRack Installation and Operation AWS Remote ModeNavigating in the Setup menu Setup/MIDI ModeOption Display Setting OverviewSaving Setups to a Mac or PC sa Default Midi Controller MappingMidi m1 Midi Remote Channel ckRemote Mode re Write Protect Mode prTest Mode te Address Setting adTest LEDs tl Test Pots tpSet DIM Level d1 Show Version veBefore continuing see System Requirements overleaf Software Download and InstallationAn be downloaded from Miscellaneous Rack Connector DetailsRack Internal Links and Fuses Rack Connector Details Mix Bus Link Environmental Specification Physical SpecificationPage MIC Section E Rack Mic Amp ModuleLine Section F A-1Output Section H 3 HF/LF Section GA-2 Measurement References Measurement ConditionsMicrophone Amplifier Performance A-3Line Input Performance Instrument Input PerformanceA-4 A-5 A-6 Connector DetailsFrequency Sections Rack EQ ModuleB-1 B-2 Curves PerformanceHF Band controls HMF Band controlsLF Band controls LMF Band controlsB-4 HF EQ Maximum Gain EQ AlignmentHMF EQ Maximum Gain LMF EQ Maximum Gain‘Balance’ Adaptor LF EQ Maximum GainB-6 B-7 B-8 Compressor/Limiter Section Rack Dynamics ModuleGate/Expander Section D-1D-2 Expander/Gate Controls Compressor/Limiter ControlsD-3 Distortion Dynamics AdjustmentsD-4 Compressor Law Compressor ThresholdGate Threshold 7 ‘Balance’ AdaptorD-6 Introduction Line Return ModuleOperation Rack Line Return ModuleE-2 Measurement Conditions Performance SpecificationMeasurement References Line Input PerformanceLine Input Calibration InformationLine E-4Line Connector DetailsInsert Send/Return E-5E-6 Overall width front and rear panels are offsetRack Master Module Master ModuleMix Section F-1Monitor Section Configuration Dim LevelExpansion Midi RemoteLevel Compensation Default Midi Controller Mapping600Ω Output Level Compensation F-3Record Bus Performance Mix Bus PerformanceF-4 Meter Level Mix Level TrackingHeadphones Connector Details Ins Rtn, Ext, Mon, Alt MonIns Snd, Mix, Rec, Fol Mon F-6F-7 F-8