Solid State Logic X-Logic Series owner manual Dynamics Adjustments, Distortion, D-4

Page 42

X-Rack Owner’s Manual

D.3.5 Measurement Conditions

Signal applied to Input, output measured at Output. All pots anti-clockwise and switches ‘out’ except for Dynamics ‘in’.

THD + N (+10dBu applied)

< 0.01% at 1kHz

Signal at +20dBu applied to Input, Compressor Threshold set at –20, Compressor Ratio adjusted to give +4dBu at Output. RMS sensing mode selected.

THD + N

< 0.3% at 1kHz

(Fast Attack Mode) †

< 0.05% at 10kHz

THD + N

< 0.03% at 1kHz

(Slow Attack Mode)

< 0.05% at 10kHz

† LF distortion is consistent with attack and release time constants.

Output Headroom

> +26dBu at onset of clipping

Frequency Response

±0.2dB from 20Hz to 20kHz

–3dB at 130kHz

 

Noise

< –88dBu

D.4 Calibration Information

The X-Rack Dynamics module is factory calibrated and should only need calibration if a potentiometer or other component has been replaced or if it is suspected that there is a problem with calibration.

In each of the following instructions it is assumed that the lid has been removed and that power has been applied. It is also assumed that unless otherwise specified, all switches are released and all front panel potentiometers are at unity or minimum position as appropriate. The required accuracy for each adjustment will be specified along with the target value. All level and distortion measurements should be made with audio-band 20Hz to 20kHz filters unless otherwise specified.

All presets are accessible from the top of the unit.

Note. The unit should be allowed to warm up with power applied for at least 15 minutes prior to any adjustments being made.

D.4.1 Dynamics Adjustments

If the dynamics circuitry requires adjustment the following procedure should be followed in the order shown. All presets are on the 629618 card.

Equipment Required:

 

Calibrated audio oscillator, audio distortion analyser, audio level meter,

 

 

oscilloscope and a (digital) DC volt meter.

Test Signal:

 

1kHz sine wave unless specified otherwise, level as specified.

Input and Output:

 

Oscillator to Input A (or B), Output to either the distortion analyser or the

 

 

level meter, as specified below. Use the oscilloscope to monitor the

 

 

measured signal.

Unit Setup:

 

Switch the dynamics IN and the EQ and Filter sections OUT, set all of the

 

 

dynamics controls anti-clockwise and release all switches.

D.4.2 Distortion

 

 

Adjustment:

1.

Connect the distortion analyser to the Output and set the oscillator level

 

 

for +20dBu.

 

2.

Adjust VR12 for minimum distortion (< 0.02%).

Page D-4

Image 42
Contents Page Page Solid State Logic U N D V I S I O NSolid State Logic Contents XLogic Out of Warranty Repairs WarrantyWarranty Repairs IntroductionInstallation Safety considerationsElectrical Safety Warning DefinitionsMains Supply and Phases Graphical SymbolsSafety Considerations Mains Isolation and Over-Current ProtectionRack Installation Assembling the X-RackMounting Connection Operation Total Recall Stand-alone ModeExiting Display Mode Saving Stores to Internal MemoryAWS Remote Mode Rack Installation and OperationOption Display Setting Setup/MIDI ModeNavigating in the Setup menu OverviewMidi m1 Default Midi Controller MappingSaving Setups to a Mac or PC sa Midi Remote Channel ckWrite Protect Mode pr Remote Mode reTest LEDs tl Address Setting adTest Mode te Test Pots tpShow Version ve Set DIM Level d1Software Download and Installation Before continuing see System Requirements overleafAn be downloaded from Rack Connector Details MiscellaneousRack Internal Links and Fuses Rack Connector Details Mix Bus Link Physical Specification Environmental SpecificationPage Line Section F Rack Mic Amp ModuleMIC Section E A-13 HF/LF Section G Output Section HA-2 Microphone Amplifier Performance Measurement ConditionsMeasurement References A-3Instrument Input Performance Line Input PerformanceA-4 A-5 Connector Details A-6Rack EQ Module Frequency SectionsB-1 B-2 HF Band controls PerformanceCurves HMF Band controlsLMF Band controls LF Band controlsB-4 HMF EQ Maximum Gain EQ AlignmentHF EQ Maximum Gain LMF EQ Maximum GainLF EQ Maximum Gain ‘Balance’ AdaptorB-6 B-7 B-8 Gate/Expander Section Rack Dynamics ModuleCompressor/Limiter Section D-1D-2 Compressor/Limiter Controls Expander/Gate ControlsD-3 Dynamics Adjustments DistortionD-4 Gate Threshold Compressor ThresholdCompressor Law 7 ‘Balance’ AdaptorD-6 Operation Line Return ModuleIntroduction Rack Line Return ModuleE-2 Measurement References Performance SpecificationMeasurement Conditions Line Input PerformanceLine Calibration InformationLine Input E-4Insert Send/Return Connector DetailsLine E-5Overall width front and rear panels are offset E-6Mix Section Master ModuleRack Master Module F-1Expansion Configuration Dim LevelMonitor Section Midi Remote600Ω Output Level Compensation Default Midi Controller MappingLevel Compensation F-3Mix Bus Performance Record Bus PerformanceF-4 Mix Level Tracking Meter LevelIns Snd, Mix, Rec, Fol Mon Connector Details Ins Rtn, Ext, Mon, Alt MonHeadphones F-6F-7 F-8