Solid State Logic X-Logic Series Midi m1, Midi Remote Channel ck, Midi Remote Learn ck

Page 15

X-Rack Installation and Operation

4.4.2MIDI (m1)

Under this menu it is possible to set the MIDI controls which can control parts of the X-Rack XR622 Master module and also to save and load all internal stores to and from a MIDI sequencer or librarian as a SysEx dump.

MIDI Remote Channel (ck)

Under the MIDI menu, use th e D-Pot to select MIDI Channel.

Then press the D-Pot and turn it to select the required channel (‘01 to ‘16’ or ‘al’ for all/any channel). This is the MIDI channel that will

be used for remote control of the XR622 Master module. By default X-Rack will listen on all channels.

MIDI Remote Learn (ck)

 

 

 

 

 

 

 

 

 

Under the MI

DI men u, use the D-P ot t o s elect

 

 

 

 

 

 

 

 

 

 

+

 

MIDI Learn (

le) an d p ress SAVE. T he gr een

 

 

 

 

 

 

Wr Prot’ LED will flash to indicate you are in MIDI

 

 

 

 

 

 

Learn mode. Operating any one of the ‘soft’ controls

 

 

 

 

 

 

SAVE

 

 

 

 

on the XR622 Master module will c ause the LED of

 

 

 

 

 

the selected control to flash (the module ‘ SEL’ LED

 

 

 

 

 

will flash if either of the potentiomenters have been chosen) – indicating it has been chosen. Assign a MIDI

controller t o the select ed fu nction by oper ating the required MIDI controller. To cancel or change the

assignment either operate the Master module control again, or operate a different control. A successful

assignment will be indicated by the flashing LED changing to just being illuminated steadily.

To exit MIDI Learn mode, press the D-Pot – the green ‘Wr Prot’ LED will stop flashing. Switch assignments

can be reset to the system defaults by pressing COPY/DEL when in MIDI Remote Learn mode; the ‘Empty

LED indicating when the assignments have been deleted.

 

 

 

 

 

 

 

Default MIDI Controller Mapping

 

 

 

 

 

 

 

MIDI Controller

 

Master Module Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

MIX

 

 

 

 

 

 

 

2

 

REC

 

 

 

 

 

 

 

3

 

EXT

 

 

 

 

 

 

 

4

 

ALT

 

 

 

 

 

 

 

5

 

MONO

 

 

 

 

 

 

 

6

 

DIM

 

 

 

 

 

 

 

7

 

CUT

 

 

 

 

 

 

 

8

 

AFL Level

 

 

 

 

 

 

 

9

 

Monitor LEVEL

 

 

 

 

 

MIDI Save and Load

In order to use t he MIDI save and l oad utility th e X-Rack must be conn ected to a c omputer running a suitable sequencer or MIDI librarian package.

All the stored setups can be saved as a Sy stem Exclusive dump to any software pac kage that supports MIDI SysEx dumps. In practice this includes most packages and you would normally save the TR setups to an additional track in your current DAW project so that your setups are sto red with the rest of the project.

Saving Setups to a Mac or PC (sa)

With the X-Rack in Setup Mode, saving TR setups to Mac or PC can be achieved as follows:

• Under the MIDI menu, use the D-Pot to select MIDI Save.

Page 11

Image 15
Contents Page Page U N D V I S I O N Solid State LogicSolid State Logic Contents XLogic Introduction WarrantyWarranty Repairs Out of Warranty RepairsDefinitions Safety considerationsElectrical Safety Warning InstallationMains Isolation and Over-Current Protection Graphical SymbolsSafety Considerations Mains Supply and PhasesRack Installation Assembling the X-RackMounting Connection Saving Stores to Internal Memory Stand-alone Mode Exiting Display Mode Operation Total RecallRack Installation and Operation AWS Remote ModeOverview Setup/MIDI ModeNavigating in the Setup menu Option Display SettingMidi Remote Channel ck Default Midi Controller MappingSaving Setups to a Mac or PC sa Midi m1Remote Mode re Write Protect Mode prTest Pots tp Address Setting adTest Mode te Test LEDs tlSet DIM Level d1 Show Version veBefore continuing see System Requirements overleaf Software Download and InstallationAn be downloaded from Rack Connector Details MiscellaneousRack Internal Links and Fuses Rack Connector Details Mix Bus Link Environmental Specification Physical SpecificationPage A-1 Rack Mic Amp ModuleMIC Section E Line Section F3 HF/LF Section G Output Section HA-2 A-3 Measurement ConditionsMeasurement References Microphone Amplifier PerformanceInstrument Input Performance Line Input PerformanceA-4 A-5 A-6 Connector DetailsRack EQ Module Frequency SectionsB-1 B-2 HMF Band controls PerformanceCurves HF Band controlsLMF Band controls LF Band controlsB-4 LMF EQ Maximum Gain EQ AlignmentHF EQ Maximum Gain HMF EQ Maximum GainLF EQ Maximum Gain ‘Balance’ AdaptorB-6 B-7 B-8 D-1 Rack Dynamics ModuleCompressor/Limiter Section Gate/Expander SectionD-2 Compressor/Limiter Controls Expander/Gate ControlsD-3 Dynamics Adjustments DistortionD-4 7 ‘Balance’ Adaptor Compressor ThresholdCompressor Law Gate ThresholdD-6 Rack Line Return Module Line Return ModuleIntroduction OperationE-2 Line Input Performance Performance SpecificationMeasurement Conditions Measurement ReferencesE-4 Calibration InformationLine Input LineE-5 Connector DetailsLine Insert Send/ReturnE-6 Overall width front and rear panels are offsetF-1 Master ModuleRack Master Module Mix SectionMidi Remote Configuration Dim LevelMonitor Section ExpansionF-3 Default Midi Controller MappingLevel Compensation 600Ω Output Level CompensationMix Bus Performance Record Bus PerformanceF-4 Meter Level Mix Level TrackingF-6 Connector Details Ins Rtn, Ext, Mon, Alt MonHeadphones Ins Snd, Mix, Rec, Fol MonF-7 F-8