Solid State Logic X-Logic Series Rack Mic Amp Module, MIC Section E, Line Section F, A-1

Page 25

X-Rack Mic Amp Module

A. The Mic Amp Module

A.1 Connection

The rear panel of the module carries the Mic (‘IN’) and Line input (‘LINE’) XLRs along with a single output (‘OUT’) XLR. The Line input and output operate at a nominal level of +4dBu although the gain of the Line input can be varied by a front panel control. Also contained on the front panel is an additional mono Jack socket for a high impedance Instrument input.

A.2 Operation

The X-Rack Mic module contains three seperate input amplifiers; a Microphone amplifier, an Instrument input and a Line input, any one of which may be selected at any one time. A set of High and Low Pass filters are also provided.

A.2.1 MIC Section E

Normally, the Microphone input on the rear of the module will be selected (‘LINE’ and ‘INST’ switches released); pressing the ‘INST’ switch selects the mono jack instrument input on the front of the module. This is a very high impedance unbalanced input intended to be used with guitar pickups etc. To help alleviate ‘hum’, a ground lift (‘GND LFT’) switch has been provided which places a 1k2Ω impedance in series with the sleeve of this connector and audio ground in the module. The gain of these inputs is continuously variable between +12dB and +75dB.

The impedance of the Microphone input can be varied between ≈1k2Ω and ≈10kΩ by selecting the ‘IMP IN’ switch and adjusting the ‘Z’ control. This allows the connection of line level signals to the Microphone input if required, and provides an alternative input impedance for some dynamic microphones.

The ‘PAD’ switch reduces the signal level of both the Microphone or Instrument inputs by 20dB. Phantom power, for microphones requiring this, can be switched on using the ‘+48V’ switch. Please note that X-Rack units prior to serial number XRK0110 are not normally enabled for +48V. However, a field retrofit kit (629620XR) is available for these units. Any in-warrantyX-Rack units can be upgraded free-of-charge; for units out of warranty a charge will be made. Please contact your local distributor to order this kit, if required.

Note. Please note that connecting a microphone to the X-Rack Mic module with phantom power switched on is not advised as it may cause damage to either the microphone or the input stage of the X-Rack module. Take care not to connect line level sources (keyboards etc.) to the microphone input with phantom power switched on as this may damage the output stage of the connected unit.

A.2.2 LINE Section F

XR621

 

 

MIC

 

E

INST

 

 

IMP

 

 

IN

Z

HI

LO

+48V

 

 

PAD

 

 

+12

dB

+75

LINE

 

F

LINE

 

 

-20

dB

+20

Ø

HF

9 6

30

4

IN

50 KHz 3

LF

160 300

60

IN

30 600

OUTPUT

REC

L

SIGNAL

REC

R

INSTRUMENT

GND

LIFT

The Line input on the rear of the module is selected by pressing the ‘LINE’ switch. The gain of this input can be varied by ±20dB from the nominal 0dB.

The Ø (Phase) switch reverses the phase of the selected input.

Page A-1

Image 25
Contents Page Page U N D V I S I O N Solid State LogicSolid State Logic Contents XLogic Warranty Repairs WarrantyOut of Warranty Repairs IntroductionElectrical Safety Warning Safety considerationsInstallation DefinitionsSafety Considerations Graphical SymbolsMains Supply and Phases Mains Isolation and Over-Current ProtectionAssembling the X-Rack Rack InstallationMounting Connection Exiting Display Mode Stand-alone ModeOperation Total Recall Saving Stores to Internal MemoryRack Installation and Operation AWS Remote ModeNavigating in the Setup menu Setup/MIDI ModeOption Display Setting OverviewSaving Setups to a Mac or PC sa Default Midi Controller MappingMidi m1 Midi Remote Channel ckRemote Mode re Write Protect Mode prTest Mode te Address Setting adTest LEDs tl Test Pots tpSet DIM Level d1 Show Version veBefore continuing see System Requirements overleaf Software Download and InstallationAn be downloaded from Miscellaneous Rack Connector DetailsRack Internal Links and Fuses Rack Connector Details Mix Bus Link Environmental Specification Physical SpecificationPage MIC Section E Rack Mic Amp ModuleLine Section F A-1Output Section H 3 HF/LF Section GA-2 Measurement References Measurement ConditionsMicrophone Amplifier Performance A-3Line Input Performance Instrument Input PerformanceA-4 A-5 A-6 Connector DetailsFrequency Sections Rack EQ ModuleB-1 B-2 Curves PerformanceHF Band controls HMF Band controlsLF Band controls LMF Band controlsB-4 HF EQ Maximum Gain EQ AlignmentHMF EQ Maximum Gain LMF EQ Maximum Gain‘Balance’ Adaptor LF EQ Maximum GainB-6 B-7 B-8 Compressor/Limiter Section Rack Dynamics ModuleGate/Expander Section D-1D-2 Expander/Gate Controls Compressor/Limiter ControlsD-3 Distortion Dynamics AdjustmentsD-4 Compressor Law Compressor ThresholdGate Threshold 7 ‘Balance’ AdaptorD-6 Introduction Line Return ModuleOperation Rack Line Return ModuleE-2 Measurement Conditions Performance SpecificationMeasurement References Line Input PerformanceLine Input Calibration InformationLine E-4Line Connector DetailsInsert Send/Return E-5E-6 Overall width front and rear panels are offsetRack Master Module Master ModuleMix Section F-1Monitor Section Configuration Dim LevelExpansion Midi RemoteLevel Compensation Default Midi Controller Mapping600Ω Output Level Compensation F-3Record Bus Performance Mix Bus PerformanceF-4 Meter Level Mix Level TrackingHeadphones Connector Details Ins Rtn, Ext, Mon, Alt MonIns Snd, Mix, Rec, Fol Mon F-6F-7 F-8