Solid State Logic X-Logic Series Setup/MIDI Mode, Overview, Navigating in the Setup menu

Page 14

X-Rack Owner’s Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.4

Setup/MIDI Mode

 

 

 

 

 

 

4.4.1

Overview

 

 

 

 

 

 

 

 

 

Enter SETUP/MIDI mode by holding down the SETUP/MIDI switch

 

 

 

 

 

till the display reads ‘5e’. The SETUP/MIDI LED flashes to show you

 

 

 

 

 

are in this mode. Press and hold the same s witch to return to nor mal

 

 

 

 

 

operation.

 

 

 

SETUP/

 

 

 

 

 

Navigating in the Setup menu

 

MIDI

 

 

 

 

 

 

 

 

 

 

 

 

The set up menu co ntains a n umber of opt ions. Th ese eac h co ntain a number of sub-optio ns. Turn the

 

D-Pot to scroll through the main list of options and push the D-Pot to select an option for editing. The D-

 

Pot will now scroll through the available list of possible settings for that option. Pressing the D-Pot again

 

will save the currently selected setting and return to the normal option menu. The options are:

 

 

 

 

Option

Display

Setting

Notes

 

 

 

 

 

Enter Setup

5e

None

Select the MIDI channel to listen to for

 

MIDI

m1

MIDI Channel (ck)

 

 

 

 

 

remote c ontrol of the

XR622 Master

 

 

 

 

MIDI Learn (le)

module (01 to 16 or al for all)

 

 

 

 

Define whic h MIDI con trols oper ate

 

 

 

 

Save (sa) and Load (l0)

the XR622 Monitor module controls

 

 

 

 

Send or receive SysEx data to

save or

 

 

 

 

 

load a ll i nternal s tores to

a

M IDI

 

Write Protect

 

 

Off (0f) and On (0n)

sequencer or librarian

 

 

 

 

 

pr

Toggles write protect on and off

 

Remote

re

Off (0f), On (0n) or MIDI (m1)

Toggles remote T otal Recall

mode on

 

 

 

 

 

and off or enables MIDI remote control

 

Set Address

 

 

a1, a2, a3, a4

of the XR622 Monitor module controls

 

ad

Sets X-Rack address

f or AWS Total

 

Show Version

 

 

 

Recall interface

 

 

 

 

 

ve

Test LEDs (tl)

Displays software version

 

 

 

 

Test

te

All module LEDs flash

 

 

 

 

 

 

 

Test switches (t5)

Press TR computer switc hes to light

 

 

 

 

Test pots (tp)

corresponding LEDs

 

 

 

 

 

Update Software

 

 

Shows position of pots

 

 

 

 

fl

Program upgrade mode (te)

The only exit from this mode, without

 

 

 

 

 

updating the X-Rack s oftware, is to

 

Dim Level

 

 

–3 (03) to –30 (30) dB

power-cycle the unit.

 

 

XR622

 

d1

Sets the ‘DIM’ level for the

 

 

 

 

 

 

Monitor module

 

 

 

 

Page 10

Image 14
Contents Page Page Solid State Logic U N D V I S I O NSolid State Logic Contents XLogic Out of Warranty Repairs WarrantyWarranty Repairs IntroductionInstallation Safety considerationsElectrical Safety Warning DefinitionsMains Supply and Phases Graphical SymbolsSafety Considerations Mains Isolation and Over-Current ProtectionMounting Rack InstallationAssembling the X-Rack Connection Operation Total Recall Stand-alone ModeExiting Display Mode Saving Stores to Internal MemoryAWS Remote Mode Rack Installation and OperationOption Display Setting Setup/MIDI ModeNavigating in the Setup menu OverviewMidi m1 Default Midi Controller MappingSaving Setups to a Mac or PC sa Midi Remote Channel ckWrite Protect Mode pr Remote Mode reTest LEDs tl Address Setting adTest Mode te Test Pots tpShow Version ve Set DIM Level d1Software Download and Installation Before continuing see System Requirements overleafAn be downloaded from Rack Internal Links and Fuses Rack Connector DetailsMiscellaneous Rack Connector Details Mix Bus Link Physical Specification Environmental SpecificationPage Line Section F Rack Mic Amp ModuleMIC Section E A-1A-2 3 HF/LF Section GOutput Section H Microphone Amplifier Performance Measurement ConditionsMeasurement References A-3A-4 Instrument Input PerformanceLine Input Performance A-5 Connector Details A-6B-1 Rack EQ ModuleFrequency Sections B-2 HF Band controls PerformanceCurves HMF Band controlsB-4 LMF Band controlsLF Band controls HMF EQ Maximum Gain EQ AlignmentHF EQ Maximum Gain LMF EQ Maximum GainB-6 LF EQ Maximum Gain‘Balance’ Adaptor B-7 B-8 Gate/Expander Section Rack Dynamics ModuleCompressor/Limiter Section D-1D-2 D-3 Compressor/Limiter ControlsExpander/Gate Controls D-4 Dynamics AdjustmentsDistortion Gate Threshold Compressor ThresholdCompressor Law 7 ‘Balance’ AdaptorD-6 Operation Line Return ModuleIntroduction Rack Line Return ModuleE-2 Measurement References Performance SpecificationMeasurement Conditions Line Input PerformanceLine Calibration InformationLine Input E-4Insert Send/Return Connector DetailsLine E-5Overall width front and rear panels are offset E-6Mix Section Master ModuleRack Master Module F-1Expansion Configuration Dim LevelMonitor Section Midi Remote600Ω Output Level Compensation Default Midi Controller MappingLevel Compensation F-3F-4 Mix Bus PerformanceRecord Bus Performance Mix Level Tracking Meter LevelIns Snd, Mix, Rec, Fol Mon Connector Details Ins Rtn, Ext, Mon, Alt MonHeadphones F-6F-7 F-8