Solid State Logic X-Logic Series owner manual Calibration Information, Line Input, E-4

Page 48

X-Rack Owner’s Manual

E.5

E.5.1

E.5.2

E.5.3

E.5.4

E.5.5

Calibration Information

 

The X-Rack Line Return module is factory calibrated and should only need calibration if a potentiometer

or other component has been replaced or if it is suspected that there is a problem with calibration.

In each of the following instructions it is assumed that an X-Rack Master module is also fitted to the

X-Rack and that power has been applied. It is also assumed that unless otherwise specified, all switches

are released and all front panel potentiometers are at unity or minimum position as appropriate. The

required accuracy for each adjustment will be specified along with the target value. All level and

distortion measurements should be made with audio-band 20Hz to 20kHz filters unless otherwise

specified.

 

 

These presets are not accessible from the top of the unit, access to the right-hand side of the module will

be required for adjustment.

 

 

Line Input

 

Calibrated audio oscillator and audio level meter

Equipment Required:

 

Test Signal:

 

1kHz sinewave @ 0dBu

Input and Output:

 

Oscillator to Line Input

 

 

Output to the audio level meter from Master module Mix Bus Insert Send

Unit Setup:

1.

(use Left or Right as instructed below)

Set each Level control to indent (0dB).

Line 1

2.

Set each Pan control Left.

1.

Measure Insert Send Left and adjust VR9 for 0dBu ±0.1dB.

Adjustment:

 

2.

Set the Pan control to Centre and adjust VR14 for –4.5dBu ± 0.1dB.

 

3.

Measure Insert Send Right and adjust VR13 for –4.5dBu ± 0.1dB.

Line 2

4.

Repeat each step until correct.

1.

Measure Insert Send Left and adjust VR10 for 0dBu ± 0.1dB.

Adjustment:

 

2.

Set the Pan control to Centre and adjust VR16 for –4.5dBu ± 0.1dB.

 

3.

Measure Insert Send Right and adjust VR15 for –4.5dBu ± 0.1dB.

Line 3

4.

Repeat each step until correct.

1.

Measure Insert Send Left and adjust VR11 for 0dBu ± 0.1dB.

Adjustment:

 

2.

Set the Pan control to Centre and adjust VR17 for –4.5dBu ± 0.1dB.

 

3.

Measure Insert Send Right and adjust VR18 for –4.5dBu ± 0.1dB.

Line 4

4.

Repeat each step until correct.

1.

Measure Insert Send Left and adjust VR12 for 0dBu ± 0.1dB.

Adjustment:

 

2.

Set the Pan control to Centre and adjust VR19 for –4.5dBu ± 0.1dB.

 

3.

Measure Insert Send Right and adjust VR20 for –4.5dBu ± 0.1dB.

 

4.

Repeat each step until correct.

Page E-4

Image 48
Contents Page Page Solid State Logic U N D V I S I O NSolid State Logic Contents XLogic Warranty Warranty RepairsOut of Warranty Repairs IntroductionSafety considerations Electrical Safety WarningInstallation DefinitionsGraphical Symbols Safety ConsiderationsMains Supply and Phases Mains Isolation and Over-Current ProtectionRack Installation Assembling the X-RackMounting Connection Stand-alone Mode Exiting Display ModeOperation Total Recall Saving Stores to Internal MemoryAWS Remote Mode Rack Installation and OperationSetup/MIDI Mode Navigating in the Setup menuOption Display Setting OverviewDefault Midi Controller Mapping Saving Setups to a Mac or PC saMidi m1 Midi Remote Channel ckWrite Protect Mode pr Remote Mode reAddress Setting ad Test Mode teTest LEDs tl Test Pots tpShow Version ve Set DIM Level d1Software Download and Installation Before continuing see System Requirements overleafAn be downloaded from Rack Connector Details MiscellaneousRack Internal Links and Fuses Rack Connector Details Mix Bus Link Physical Specification Environmental SpecificationPage Rack Mic Amp Module MIC Section ELine Section F A-13 HF/LF Section G Output Section HA-2 Measurement Conditions Measurement ReferencesMicrophone Amplifier Performance A-3Instrument Input Performance Line Input PerformanceA-4 A-5 Connector Details A-6Rack EQ Module Frequency SectionsB-1 B-2 Performance CurvesHF Band controls HMF Band controlsLMF Band controls LF Band controlsB-4 EQ Alignment HF EQ Maximum GainHMF EQ Maximum Gain LMF EQ Maximum GainLF EQ Maximum Gain ‘Balance’ AdaptorB-6 B-7 B-8 Rack Dynamics Module Compressor/Limiter SectionGate/Expander Section D-1D-2 Compressor/Limiter Controls Expander/Gate ControlsD-3 Dynamics Adjustments DistortionD-4 Compressor Threshold Compressor LawGate Threshold 7 ‘Balance’ AdaptorD-6 Line Return Module IntroductionOperation Rack Line Return ModuleE-2 Performance Specification Measurement ConditionsMeasurement References Line Input PerformanceCalibration Information Line InputLine E-4Connector Details LineInsert Send/Return E-5Overall width front and rear panels are offset E-6Master Module Rack Master ModuleMix Section F-1Configuration Dim Level Monitor SectionExpansion Midi RemoteDefault Midi Controller Mapping Level Compensation600Ω Output Level Compensation F-3Mix Bus Performance Record Bus PerformanceF-4 Mix Level Tracking Meter LevelConnector Details Ins Rtn, Ext, Mon, Alt Mon HeadphonesIns Snd, Mix, Rec, Fol Mon F-6F-7 F-8