Introduction

Used in conjunction with the XR623 X-Rack Line Return module, the XR622 X-Rack Master module provides a complete small scale mix and monitor system for studios seeking a compact solution for mixing and monitoring in the analogue domain. A single X-Rack can provide up to 28 line level inputs. Additional racks can be connected via the ‘MIX BUS LINK’ connector on the rear of the X-Rack unit, allowing additional inputs to be added to the system if required.

X-Rack units prior to serial number XRK0110 are not equipped with a ‘MIX BUS LINK’ connector.

The X-Rack Total Recall system allows session setups to be recalled instantly and can be archived as a

MIDI SysEx dump to any MIDI sequencer. The monitor section controls can also be controlled remotely

using MIDI controller commands from any MIDI controller. Up to three racks can be connected to an

AWS 900 or AWS 900+ and integrated with the AWS 900 Total Recall system via the serial port. Connecting

the MIX and REC outputs of the XR-622 to the MIX and REC Insert Returns of the AWS 900 and selecting

INSERT SUM mode allows almost unlimited expansion of the number of line level inputs to the console.

Connection

The rear panel of the module carries a pair of 25-way ‘D’ connectors. The left-hand

INS RTN

INS SND

EXT

MIX

connector provides the main and alternate Monitor outputs as well as a stereo External

ALT MON FOL MON

Input and the Mix Bus Insert Return. The right-hand connector provides Mix and

MON

REC

Record Bus outputs along with the Mix Bus Insert Send and a Follow-Monitor (pre-

 

 

level control) output.

 

 

 

 

 

All outputs (apart from the headphone output) operate at a nominal level of +4dBu

 

 

and are configured to drive standard line level inputs. Level compensation for feeding

 

 

600Ω inputs from the Bus, Insert and Monitor outputs is provided by removable

 

 

jumpers – refer to Section F.3.4 for details.

 

 

 

 

 

 

XR622

 

 

 

 

 

SEL

 

 

Operation

 

 

0

 

 

 

18

 

 

 

 

 

3

 

 

 

 

 

6

 

 

 

 

 

9

 

As well as a compact stereo monitor section, the X-Rack Master module contains the

 

12

 

 

42

 

 

 

 

 

15

 

mix amps and outputs for the X-Rack’s internal Mix, Record and Solo/AFL busses.

 

24

 

 

MONITOR

 

 

 

 

 

30

 

 

 

 

 

36

 

The Mix bus is intended to be used as the main mix bus and includes a balanced

SUM

48

 

insert point immediately before the Mix level control. The Record bus provides a

MIX

1

REC

direct path to a DAW (or any other recorder), allowing the Mix bus to be used to

MON

MIX LEVEL

provide a monitor mix while recording one or more inputs via the Record bus.

INS

 

 

If the X-Rack is fitted with XR621 Mic Amp modules these can be routed directly to

SUM

 

 

the Record bus using the ‘REC L’ and ‘REC R’ switches on the XR621 module.

INS

 

 

MONITOR

 

Mix Section 1

 

REC

AFL

 

This section carries all of the Mix bus controls; the ‘MIX LEVEL’ control allows the

MIX

 

SOLO

EXT

 

 

overall gain of the Mix bus to be adjusted (the Record bus level is fixed).

 

LEVEL

 

The ‘INS’ switch brings the Mix Bus Insert Return into circuit (the Insert Send is

ALT

 

 

permanently active) whilst the ‘SUM REC’ and ‘INS SUM’ switches allow the

MONO

 

 

Record bus and Insert Return to be summed with the Mix bus to allow for summing

DIM

 

 

of additional mix sources.

 

 

 

The ‘MON’ switch enables the Mix output to be replaced with whichever source(s)

CUT

 

 

have been selected for the Monitor section.

 

 

 

Page F-1

Image 51
Contents Page Page U N D V I S I O N Solid State LogicSolid State Logic Contents XLogic Introduction WarrantyWarranty Repairs Out of Warranty RepairsDefinitions Safety considerationsElectrical Safety Warning InstallationMains Isolation and Over-Current Protection Graphical SymbolsSafety Considerations Mains Supply and PhasesRack Installation Assembling the X-RackMounting Connection Saving Stores to Internal Memory Stand-alone ModeExiting Display Mode Operation Total RecallRack Installation and Operation AWS Remote ModeOverview Setup/MIDI ModeNavigating in the Setup menu Option Display SettingMidi Remote Channel ck Default Midi Controller MappingSaving Setups to a Mac or PC sa Midi m1Remote Mode re Write Protect Mode prTest Pots tp Address Setting adTest Mode te Test LEDs tlSet DIM Level d1 Show Version veBefore continuing see System Requirements overleaf Software Download and InstallationAn be downloaded from Rack Connector Details MiscellaneousRack Internal Links and Fuses Rack Connector Details Mix Bus Link Environmental Specification Physical SpecificationPage A-1 Rack Mic Amp ModuleMIC Section E Line Section F3 HF/LF Section G Output Section HA-2 A-3 Measurement ConditionsMeasurement References Microphone Amplifier PerformanceInstrument Input Performance Line Input PerformanceA-4 A-5 A-6 Connector DetailsRack EQ Module Frequency SectionsB-1 B-2 HMF Band controls PerformanceCurves HF Band controlsLMF Band controls LF Band controlsB-4 LMF EQ Maximum Gain EQ AlignmentHF EQ Maximum Gain HMF EQ Maximum GainLF EQ Maximum Gain ‘Balance’ AdaptorB-6 B-7 B-8 D-1 Rack Dynamics ModuleCompressor/Limiter Section Gate/Expander SectionD-2 Compressor/Limiter Controls Expander/Gate ControlsD-3 Dynamics Adjustments DistortionD-4 7 ‘Balance’ Adaptor Compressor ThresholdCompressor Law Gate ThresholdD-6 Rack Line Return Module Line Return ModuleIntroduction OperationE-2 Line Input Performance Performance SpecificationMeasurement Conditions Measurement References E-4 Calibration Information Line Input LineE-5 Connector DetailsLine Insert Send/ReturnE-6 Overall width front and rear panels are offsetF-1 Master ModuleRack Master Module Mix SectionMidi Remote Configuration Dim LevelMonitor Section ExpansionF-3 Default Midi Controller MappingLevel Compensation 600Ω Output Level CompensationMix Bus Performance Record Bus PerformanceF-4 Meter Level Mix Level TrackingF-6 Connector Details Ins Rtn, Ext, Mon, Alt MonHeadphones Ins Snd, Mix, Rec, Fol MonF-7 F-8