X-Rack Mic Amp Module
A.4 Calibration Information
The
In each of the following instructions it is assumed that the lid of the
All presets are accessible from the top of the unit.
A.4.1 Microphone Input |
|
Equipment Required: | Calibrated audio oscillator and audio level meter |
Test Signal: | 50Hz sinewave @ |
Input and Output: | Oscillator to Mic Input and Output to the audio level meter |
Unit Setup: | Set the Mic Gain to ‘36dB’ |
CMRR Trim |
|
Adjustment: | Adjust VR7 (CMRR) for minimum level (normally < |
A.4.2 Line Input |
|
Equipment Required: | Calibrated audio oscillator and audio level meter |
Test Signal: | 1kHz sinewave @ 0dBu |
Input and Output: | Oscillator to Line Input and Output to the audio level meter |
Unit Setup: | Set the Line Gain to indent (0dB) and select ‘LINE’ |
Level Trim |
|
Adjustment: | 1. Adjust VR6 (0dB) for 0dBu ±0.05dB. |
A.4.3 Output Balance |
|
Equipment Required: | Calibrated audio oscillator, audio level meter and a ‘balance’ adaptor (see |
| below) |
Test Signal: | 1kHz sine wave at +24dBu |
Input and Output: | Oscillator to Line Input and Output to the audio level meter via the |
| ‘balance’ adaptor |
Unit Setup: | Set the Line Gain to indent (0dB) and select ‘LINE’ |
Adjustment: | Adjust VR8 (BAL) for minimum level (< 55dBr) |
A.4.4 ‘Balance’ Adaptor
For the output balance adjustment, a ‘balance’ adaptor such as that illustrated here will be required. This adaptor consists of a pair of close tolerance resistors in an
| 1 |
| 3 | – |
|
| 0V |
|
|
| |
|
| 1 |
|
|
|
From unit | 2 | 5K01** |
|
|
|
+ |
|
|
| To measuring 2 | |
under test |
| 1 | 2 | + | |
| 3 | 5K01** |
| equipment | |
|
|
|
–
1 0V
Note 1. Resistor tolerance should ideally be 0.01%
2.Absolute level measured will depend upon the input impedence of the measuring equipment.