X-Rack EQ Module
B.4 Calibration Information
The
In each of the following instructions it is assumed that the lid of the
All presets are accessible from the top of the unit.
Note. The unit should be allowed to warm up with power applied for at least 15 minutes prior to making any adjustments.
B.4.1 EQ Alignment |
|
|
|
|
Equipment Required: |
| Calibrated audio oscillator and audio level meter |
| |
Test Signal: |
| Sine wave @ |
| |
Input and Output: |
| Oscillator to Input, Output to the audio level meter |
| |
Unit Setup: | 1. | Switch the EQ IN and release all other EQ switches. |
| |
| 2. | Release the |
| |
| 3. | Set all of the Q and Frequency controls fully | ||
|
| controls to their centre indent. |
|
|
HF EQ - Maximum Gain |
|
|
|
|
Adjustment: | 1. | Set HF Gain to maximum and select HF | . Set the audio oscillator for | |
|
| 12kHz and adjust HF Frequency to find the maximum level on the audio | ||
|
| level meter. |
|
|
| 2. | Adjust VR13 (HF Q) for +20dBu ±0.25dB. |
|
|
| 3. | Reset HF Gain to its centre indent position, | and | |
|
| the audio level meter for 0dBu. |
|
|
HMF EQ - Maximum Gain
Adjustment: | 1. | Set HMF Gain to maximum and HMF Q fully |
|
| audio oscillator for 3kHz and adjust HMF Frequency to find the |
|
| maximum level on the audio level meter. |
| 2. | Adjust VR11 (HMF Q) for +21dBu ±0.25dB. |
| 3. | Reset HMF Gain to its centre indent position, |
|
| meter for 0dBu. |
LMF EQ - Maximum Gain
Adjustment: | 1. | Set LMF Gain to maximum and LMF Q fully |
|
| oscillator for 1kHz and adjust LMF Frequency to find the maximum level |
|
| on the audio level meter. |
| 2. | Adjust VR12 (LMF Q) for +21dBu ±0.25dB. |
| 3. | Reset LMF Gain to its centre indent position, |
|
| meter for 0dBu. |
(continued)