Uniden USC 2500XL T manual Setting Up Priority Channels

Page 29

Setting Up Priority Channels

When you assign "priority" to a bank channel, you designate one bank channel as your most important channel.

During scanning the UBC 2500XL T works like a "dual watch" function. It starts "sampling" or keeping track of the activity on the Priority Channel while listening to other channels. Every 2 seconds, the scanner checks the Priority Channel for activity.

If a signal is present, the Priority Channel will be monitored until the transmission ends, and scanning resumes. If DELAY is activated, scanning resumes after 2 seconds.

Note: The Priority feature is also active in Manual, Search and WX Modes.

Each bank comes with one programmable Priority Channel (the lowest channel in each bank). You can reassign Priority Channels to any bank channel if the displayed Channel Number is 200 or less (Banks 1 through 10). In multi-Priority Channel operation, the lower channel number has higher

priority .

Note: Priority settings are not erased when you turn off the scanner, or after a power failure.

To set up a Priority Channel:

1.FIrstprogram your most important frequency into a bank channel.

2.Press and hold [PAl] for more than 2.5 seconds.

A "P" appears on the display to indicate the designated channel.

Note: Any previously assigned Priority Channel within the same bank is automatically deselected.

I

27

Image 29
Contents USC 2500XL T This equipment contains a Nickel-Cadmium PrecautionsTable of Contents About Your New UBC 2500XLT Leather-like Carrying Case UnpackingAustralia Weather Channels Lets your scanner function as aAuto Store Automatically stores all active frequencies TopView Controls and IndicatorsFrontView Scan KEY @ @4 Display. Note Youcannotdeactivateall20 banks LMTLIntKV Frequency. To store the same frequency into Send KEY Hold UO WX 1 2 KHz AM NFM WFM IkeylockiSetup Mounting the Flexible Antenna Installing the Belt ClipBand Search The Search function is different from Scanning OverviewBank Scan If you have programmed channels, you Then, press Manual Programming Channels0 5 ProgrammingWith the Rotary Tuner If the selected channel already has a stored Frequency Example Set search limits of 137.000 to 144.000 MHz Ress Manual to stop scanningPress SRC to start the search HLD to stay on that frequencyPress Manual to stop scanning Auto Store feature automatically stores all activeFirst enter the lower limit by pressing 4 0 0 Press LMTDisplay. In this case, select another bank ~nother Open ChannelPress E Current channel is erased, and the display shows Deleting a Stored FrequencyPress Manual again Scann ing Weather Channel Scanning Customizing Scanner Operation Press Scan to start scanning This feature is active in Manual Mode or Scan ModeSetting Up Priority Channels To activate the Count feature Using Count to Monitor Channel ActivityTurn the scanner off before removing the Battery Pack Care and MaintenanceEvent of memory loss. If memory is lost, simply Reprogram each channelDo not use excessive amounts of water Clean the outside of the scanner with a mild detergentProblem TroubleshootingSearch Band Technical SpecificationsDisplay 137 174 222 400 520Warranty Unid~n~GP