Leica TPS400 user manual Proceeding Peg Survey, Sequence, Measure Backsight Point, Set 1 of total

Page 10

Proceeding Peg Survey

Sequence:

It defines the measuring sequence.

Options:

BFFB Backsight-Foresight-Foresight-Backsight

BFBF Backsight-Foresight-Backsight-Foresight

BBFF Backsight-Backsight-Foresight-Foresight

[OK] Leaves this dialog and proceed to the next dialog.

Sample dialog:

Measure Backsight Point

 

Information about which

 

backsight point the user has to

 

measure.

[OK] Leaves this dialog and proceed to the measure dialog.

Set 1 of total 3

Start with measurement first set of three.

[OK] Leaves this dialog and proceed to the next dialog.

TPS400 Mining Manual-1.0.0en

10

Peg Survey

Image 10
Contents TPS400 Series Quick way to start with the TPS400 Mining Programs Contents Overview Contents Symbols used in the sequence of operation How to use this manualIntroduction Introduction Peg SurveyKnown Unknown Data uploading using Mining Editor Before starting Peg SurveyStart and execution Peg Survey StepStation or BS point has no Number of sets Error messagesValid coords Measure Backsight Point Proceeding Peg SurveySequence Set 1 of totalMeasure or DIST/REC ExitRepeat and until all sets are measured DHz ResultsDHD MHz MHDBS/FS AverageResidual Results Saving dataResult Coordinates foresight pointFront Line Peg Grades KnownStart and execution Grades Slope gradient explained Gradeline Marking Height difference dHgt and horizontal distance dHD explained Point Measurement dataGrades Result Offset Start and execution Offset Start and execution Offset Saving data Offset informationSetting out coordinates from memory Procedure Setting outPolar setout Orthogonal setout Cartesian setout Result is displayed Tie DistanceRadial Method Determine second target Polygonal MethodSoftkeys polygonal method Softkeys radial methodMining Editor Installation on the PCProgram content Mining EditorExample1 Practical ExamplesDefine and upload Tolerances Example2Creating fixpoint files Define tolerances File ! Save AsFile ! Open Second Example Importing of fixpoints in Ascii format Process import fixpoint filesISO standard