Panasonic PT-LM2E OPTION2, Runtime, Time Reset, DESK/CEILING Desk FAN Control Standard Lamp, Func

Page 52

'Install the lamp unit cover, and then use a Phillips screwdriver to securely tighten the lamp unit cover fixing screws.

NOTE:

BBe sure to install the lamp unit and the lamp unit cover securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.

(Connect the mains lead.

)Press the POWER button so that a picture is projected onto the screen.

NOTE:

BIf the mains lead was disconnected during projection when the projector was used the last time, projection will start after the mains lead is connected (when “POWER MEMORY” in the “OPTION2” menu is set to “ON”). Refer to page 44 for details.

*Press the MENU button to display the “MAIN MENU”, and then press the F or G button to select “OPTION2”.

MENU

KEYSTONE

PICTURE

POSITION

INDEX WINDOW

SHUTTER

VOLUME

LANGUAGE

OPTION1

OPTION2

SECURITY

SELECTENTEREXIT

+Press the ENTER button to display the “OPTION2” menu, and then press the F or G button to select “LAMP RUNTIME”.

OPTION2

BACK COLOR BLUE

FRONT/REAR FRONT

DESK/CEILING DESK FAN CONTROL STANDARD

LAMP

POWER

HIGH

 

 

 

LAMP

RUNTIME

1820H

 

 

 

FUNC

1

INDEX

 

 

CONTROL KEY

ON

 

AUTO POW.OFF DISABLE

 

 

 

 

 

 

POWER

MEMORY

ON

SELECT

RETRN

,Press and hold the ENTER button for approximately 3 seconds.

OPTION2

BACK COLOR BLUE FRONT/REAR FRONT DESK/CEILING DESK FAN CONTROL STANDARD

LAMP

POWER

HIGH

TIME

RESET

[POWER OFF]

FUNC

1

INDEX

CONTROL KEY

ON

AUTO POW.OFF DISABLE

POWER MEMORY

ON

SELECT

RETRN

The “LAMP RUNTIME” will change to “TIME RESET [POWER OFF]”.

NOTE:

BIf the MENU button is pressed, the lamp time resetting screen will be cancelled.

-Turn off the power.

This will reset the cumulative usage time for the lamp unit to “0”.

Refer to page 24 for details on how to turn off the power.

52-ENGLISH

Image 52
Contents LCD Projector Commercial Use Model No. PT-LM2EImportant Safety Notice Dear Panasonic CustomerFor Your SAFETY, Please Read the Following Text Carefully Important the Moulded Plug U.K. onlyContents Do not overload the mains socket Precautions with regard to safetyDo not remove the cover or modify it in any way Do not handle the mains plug with wet hands Insert the mains plug securely into the mains socketDo not place the projector into water or let it become wet Do not place liquid containers on top of the projectorDo not use the projector in a bath or shower Do not look into the lens while the projector is being usedDo not cover the air inlet or the air outlet Always disconnect all cables before moving the projectorDo not put your weight on this projector Insulate the battery using tape or similar before disposalUse only the specified batteries Accessories Before use Order to get the best picture quality Do not touch the surfaces of the lens with your bare handsScreen LampLeg adjuster buttons L/R Location and function of each part# Connector panel $ Air outlet port Remote control unit Projector control panel Top Menu$ Temp indicator Lamp indicatorRGB Input indicator Auto Setup button pages 23Video in connector pages 20 Audio in L-R jacks pages 19 Power input socket ACVideo in jack Security lockSetting-up Projection methodsProjector position Projection distancesConnecting to computer ConnectionsConnecting to video equipment Preparation for the remote control unit Insert the battery holderTurning on the power $Press the Power buttonTurn on the power of all connected devices Before turning on the power 1, Ensure that all peripheralPress the input select button to select the input signal Adjusting the angleAdjusting the size Adjusting the focusTurning off the power Press the Power buttonPower indicator Projector statusPress the Auto Setup button Turning off the picture and sound momentarily Shutter Pausing a picture FreezePress the Freeze button Adjusting the volume Volume Remote control unit functions during D.ZOOM digital zoomPress the Volume +/- button Enlarging the picture D.ZOOMDisplaying two screens Index Window Press the Index Window buttonOn-screen menus Menu screensKeystone KeystoneSignal Power HighKEY Auto POW.OFF Disable OPTION1Picture Menu operation guideSelect ADJ Returning a setting to the factory default Picture ModeStandard PictureCorrecting keystone distortion Vertical keystone distortion correction onlyVertical OperationAdjusting the picture Picture ModeContrast DynamicBright ColorTint SharpnessStill Mode Signal ModeStill Mode Projecting sRGB-compatible picturesAdjusting the position Clock PhasePosition DOT ClockAspect Aspect AutoResizing Frame LockChanging the display language EnglishOption settings Auto SignalOSD Auto KeystnSxga Mode Lamp PowerBack Color FRONT/REARPower Memory Lamp RuntimeFunc Control KEYSetting up the security function Input PasswdAmend Passwd SecurityText Display Text ChangeTemp indicator Lamp indicator RemedyLamp Power Cleaning and replacing the air filter CleaningLamp unit replacement period Replacing the lamp unitLamp unit replacement procedure Lamp unit fixing screwsTime Reset OPTION2Runtime DESK/CEILING Desk FAN Control Standard LampBefore calling for service Problem Possible cause Not displayCorrectly Picture fromCleaning and maintenance Wipe the cabinet with a soft, dry clothSpecifications PAL60/SECAMRemote control unit OptionsList of compatible signals AppendixProjection dimensions calculation methods Connector pin wiringPin No Dimensions Trademark acknowledgements