October 2006 | Installing the server and connecting the peripheral devices |
Connecting the server to the CLAN (optional)
Introduction
This section provides instructions to connect the server to the CLAN.
Note: The CLAN is optional. However, a CLAN is required to support desktop and web messaging users.
ATTENTION |
| |
To comply with EMC radiation requirements, a Class A | ||
| ||
| hub must be located 10 m (33 ft.) away from the 1002rp | |
| server. Shielded Ethernet cables must be used. |
Media Access Control address
The MAC address is a unique number assigned to network cards and controllers. The procedure below asks you to record the CLAN MAC address. The MAC address is recorded on a label affixed to the back of the chassis.
To connect the server to the CLAN
1See the diagram on page 65 to locate the CLAN network connector.
2Locate the MAC address label on the back of the chassis that identifies the CLAN controller MAC address.
3Record the MAC address on the Configuration Wizard worksheet that is provided in the Installation and Configuration Task List
(555-7101-210).
1002rp Server Hardware Installation | 71 |