American Power Conversion MX06 100, MX06 50 user manual Safety First, General Precautions

Page 5

1 Safety First!

It is very important to follow all safety procedures when unpacking, installing and operating any sort of power equipment.

1.1. Warning Symbols

CAUTION: An indication that special care is required to prevent injury, equipment damage or misuse

WARNING: An indication of an electrical hazard that may cause serious personal injury or death, catastrophic equipment damage or site destruction.

1.2. General Precautions:

WARNING: Hazardous AC voltage levels are present inside the power system. Keep the rear cover in place when the system is operational or energized

WARNING: Hazardous energy levels are present on bare conductors in the -48VDC distribution connection area of the plant. Accidental shorting of distribution conductors can cause arcing and high currents that can cause serious burns or other physical harm. It is recommended that:

Remove any jewelry, rings or watches while working on this equipment.

Use insulated wrenches, screwdrivers, cutters, pliers and other tools.

WARNING: Ensure that all of the DC and external AC circuit breakers are in the OFF position prior to connecting service to the power plant. Confirm that all voltages have been removed including any battery sources before proceeding.

Specific CAUTION and WARNING will be placed in manual where appropriate.

MX06 Power Plant User’s Manual

Page 1

Image 5
Contents VDC Power Systems Table of Contents APC Worldwide Customer Support Limited Product Warranty Revision Revision HistoryGeneral Precautions Safety FirstGeneral Information IntroductionPort How to Use This Manual Mechanical Installation InstallationUnpacking Equipment Room / LocationVentilation AC Power ConnectionsConnecting the Battery Cables Battery ConnectionsPlanning the Battery installation Multiple Battery Strings Battery LVD ConnectionBattery LVD DC System Grounding Battery Temperature Probe InstallationGMT Fuse Installation Load Protection InstallationCircuit Breaker Installation Circuit Breaker Protected Load Connections 30 or 60 Amps Load ConnectionsCable Size Considerations Relay Output Connections Input / Output ConnectionsGMT Fuse protected Load Connections External Alarm Input Connections Relay J2 Connector Output Relay Notes DesignationsInitial Power-Up and Checkout Rectifier Module InstallationBattery and Load Power up Rectifier Management Technical DescriptionSystem Management Alarm FunctionsControl Functions DisplaysBattery Charging Battery ManagementBattery Temperature Compensation Load ManagementBattery Low Voltage Disconnect Operation MX06 Voltage AdjustmentsDescription MX06 OperationAlarm No Setting NC Setting Major Minor Factory MX06-50 Configuration SettingsMX06 External Alarm Input Configuration MX06-50 Programmable Alarms MX06-50 Rectifier ConfigurationAlarm Major Minor No Alarm FactoryMX06-100 Rectifier Configuration MX06-100 Configuration SettingsMX06-50 Temperature Probe Selection MX06-100 Temperature Probe Selection MX06-100 Programmable AlarmsMX06 50 Power System SpecificationsAC Input TWF0500H5401 RectifierDC Output MX06 100 Power SystemVDC MX06 Controller Controls and IndicatorsMechanical Environmental Magnum VS 50 Power SystemMagnum VS 100 Power System EMC ComplianceAPC Worldwide Customer Support Limited Product Warranty