American Power Conversion MX06 100, MX06 50 user manual Port

Page 7

 

1

UFA1

 

 

 

 

 

 

 

 

Main Power Distribution Backplane

 

2

UFA2

-BAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3

3

UFA3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER

4

UFA4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM 6

-BAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUTS

7

-BAT

+BAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

-BAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

-BAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

MAJ NC

CONTROL BUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J2

2

MAJ COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

MAJ NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM

4

MIN NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

56

MIN NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUTS 7

VLV NC

 

DC

Control

 

DC

Control

 

DC

Control

 

DC

Control

 

DC

Control

 

8

VLV COM

 

 

 

 

 

 

9

VLV NO

 

 

 

 

 

 

 

 

 

 

J5

1

YELLOW

AC

 

AC

 

AC

 

AC

 

AC

 

2

BROWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTORIZED

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREAKER 4

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLS

5

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

GND

 

 

 

 

 

GND

 

 

GND

 

J4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

TMP

 

 

 

 

TRM9

 

 

 

 

 

TRM6

 

 

TRM3

 

TEMPERATURE

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-BAT

M

S

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBE

34

+12 PWR

 

TRM7

TRM8

 

 

 

 

TRM4

TRM5

 

TRM1

TRM2

 

 

 

 

Port

Port

L1 L2/N

 

 

 

 

L1 L2/N

 

L1 L2/N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second Power Distribution Backplane

 

 

 

CONTROL BUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC

Control

 

DC

Control

 

DC

Control

 

DC

Control

 

DC

Control

 

 

 

AC

 

AC

 

AC

 

AC

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

GND

 

 

GND

 

 

 

 

 

 

 

 

TRM9

 

 

 

 

 

TRM6

 

 

TRM3

 

 

 

 

M

S

 

TRM7

TRM8

 

 

 

 

TRM4

TRM5

 

TRM1

TRM2

 

 

 

 

Port

Port

L1 L2/N

 

 

 

 

L1 L2/N

 

L1 L2/N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2.1-2 MX06 100 Block Diagram

 

 

 

 

MX06 Power Plant User’s Manual

Page 3

BATTERY (–) (orange)

(black) BATTERY (+)

Visual Alarm

One to 12 outputs

Load

Distribution

Module

BATTERY (–) (orange)

(black) BATTERY (+)

Visual Alarm

One to 12 outputs

Load

Distribution

Module

Image 7
Contents VDC Power Systems Table of Contents APC Worldwide Customer Support Limited Product Warranty Revision Revision HistoryGeneral Precautions Safety FirstGeneral Information IntroductionPort How to Use This Manual Room / Location InstallationMechanical Installation Unpacking EquipmentVentilation AC Power ConnectionsPlanning the Battery installation Battery ConnectionsConnecting the Battery Cables Multiple Battery Strings Battery LVD ConnectionBattery LVD DC System Grounding Battery Temperature Probe InstallationCircuit Breaker Installation Load Protection InstallationGMT Fuse Installation Cable Size Considerations Load ConnectionsCircuit Breaker Protected Load Connections 30 or 60 Amps GMT Fuse protected Load Connections Input / Output ConnectionsRelay Output Connections External Alarm Input Connections Relay J2 Connector Output Relay Notes DesignationsInitial Power-Up and Checkout Rectifier Module InstallationBattery and Load Power up Rectifier Management Technical DescriptionDisplays Alarm FunctionsSystem Management Control FunctionsLoad Management Battery ManagementBattery Charging Battery Temperature CompensationBattery Low Voltage Disconnect MX06 Operation MX06 Voltage AdjustmentsOperation DescriptionMX06 External Alarm Input Configuration MX06-50 Configuration SettingsAlarm No Setting NC Setting Major Minor Factory Major Minor No Alarm Factory MX06-50 Rectifier ConfigurationMX06-50 Programmable Alarms AlarmMX06-50 Temperature Probe Selection MX06-100 Configuration SettingsMX06-100 Rectifier Configuration MX06-100 Temperature Probe Selection MX06-100 Programmable AlarmsTWF0500H5401 Rectifier SpecificationsMX06 50 Power System AC InputDC Output MX06 100 Power SystemVDC Mechanical Controls and IndicatorsMX06 Controller Magnum VS 100 Power System Magnum VS 50 Power SystemEnvironmental EMC ComplianceAPC Worldwide Customer Support Limited Product Warranty