American Power Conversion MX06 50, MX06 100 user manual Environmental, Magnum VS 50 Power System

Page 34

Magnum VS 50 Power System

Dimensions

5-1/4 in (13.3 cm) high x 17-1/4 in (43.8 cm) wide x 12.5 in

 

(32 cm) deep

 

 

 

 

 

Weight

12 lbs. (5.5 Kg)

 

 

 

 

Color

Grey Front, Yellow zinc sides and back

 

 

 

Mounting

19” Rack Mounting (23” Optional)

 

 

 

 

Magnum VS 100 Power System

 

 

 

 

Dimensions

10-1/2 in (26.6 cm) high x 17-1/4 in (43.8 cm) wide x 12.5 in

 

(32 cm) deep

 

 

 

 

 

Weight

24 lbs. (11 Kg)

 

 

 

 

Color

Grey Front, Yellow zinc sides and back

 

 

 

Mounting

19” Rack Mounting (23” Optional)

 

 

 

 

6.5. Environmental

 

 

 

 

Ambient Temperature

(Operating)

-40ºC to +55ºC (+65ºC with reduced

 

 

 

power output)

 

 

(Storage)

-45ºC to +85ºC

 

 

 

 

Humidity

 

(Operating)

0 – 85% RH (non-condensing)

 

 

(Storage)

0 – 95% RH (non-condensing)

 

 

 

 

Altitude

 

(Operating)

3000 m (9840 ft.)

 

 

(Storage)

10000 m (39370 ft.)

 

 

 

 

MX06 Power Plant User’s Manual

Page 30

Image 34
Contents VDC Power Systems Table of Contents APC Worldwide Customer Support Limited Product Warranty Revision History RevisionSafety First General PrecautionsIntroduction General InformationPort How to Use This Manual Unpacking Equipment InstallationMechanical Installation Room / LocationAC Power Connections VentilationPlanning the Battery installation Battery ConnectionsConnecting the Battery Cables Battery LVD Connection Multiple Battery StringsBattery LVD Battery Temperature Probe Installation DC System GroundingCircuit Breaker Installation Load Protection InstallationGMT Fuse Installation Cable Size Considerations Load ConnectionsCircuit Breaker Protected Load Connections 30 or 60 Amps GMT Fuse protected Load Connections Input / Output ConnectionsRelay Output Connections Relay J2 Connector Output Relay Notes Designations External Alarm Input ConnectionsRectifier Module Installation Initial Power-Up and CheckoutBattery and Load Power up Technical Description Rectifier ManagementControl Functions Alarm FunctionsSystem Management DisplaysBattery Temperature Compensation Battery ManagementBattery Charging Load ManagementBattery Low Voltage Disconnect Description MX06 Voltage AdjustmentsOperation MX06 OperationMX06 External Alarm Input Configuration MX06-50 Configuration SettingsAlarm No Setting NC Setting Major Minor Factory Alarm MX06-50 Rectifier ConfigurationMX06-50 Programmable Alarms Major Minor No Alarm FactoryMX06-50 Temperature Probe Selection MX06-100 Configuration SettingsMX06-100 Rectifier Configuration MX06-100 Programmable Alarms MX06-100 Temperature Probe SelectionAC Input SpecificationsMX06 50 Power System TWF0500H5401 RectifierMX06 100 Power System DC OutputVDC Mechanical Controls and IndicatorsMX06 Controller Magnum VS 100 Power System Magnum VS 50 Power SystemEnvironmental Compliance EMCAPC Worldwide Customer Support Limited Product Warranty