American Power Conversion MX06 50, MX06 100 user manual Introduction, General Information

Page 6

2 Introduction

2.1. General Information

DC Power Plants from APC have unique features that make them easy to install, maintain, and upgrade. The rectifier units are modular and truly “hot-pluggable” into the shelf assembly without any separate AC wiring. The MX06 50 has 1 shelf, holding five rectifiers for a maximum of 52.5 Amps. The MX06 100 has 2 shelves, holding ten rectifiers for a maximum of 105 Amps. The controller provides monitoring and control functions for each component of the system.

The APC MX06 is a modular stand-alone -48 Volts DC power plant. It is configurable in such a manner that it will support most typical applications within the specified current ranges (10-100 Amperes) without special application engineering or assistance. DC output distribution is included for circuit breakers or GMT style fuses or in the 100 Amp versions, a combination of both. Available circuit breakers are 30 Amps or 60 Amps. GMT fuses can be 1/4 to15 Amps. A low voltage disconnect (LVD) is provided to disconnect the battery after deep discharge. A 50 Amp power system is shown in Figure 2.1-1. A block diagram of a typical 100 Amp power system with fuses is shown in Figure 2.1-2.

Figure 2.1-1 MX06 50 DC Power Plant

MX06 Power Plant User’s Manual

Page 2

Image 6
Contents VDC Power Systems Table of Contents APC Worldwide Customer Support Limited Product Warranty Revision History RevisionSafety First General PrecautionsIntroduction General InformationPort How to Use This Manual Unpacking Equipment InstallationMechanical Installation Room / LocationAC Power Connections VentilationBattery Connections Planning the Battery installationConnecting the Battery Cables Battery LVD Connection Multiple Battery StringsBattery LVD Battery Temperature Probe Installation DC System GroundingLoad Protection Installation Circuit Breaker InstallationGMT Fuse Installation Load Connections Cable Size ConsiderationsCircuit Breaker Protected Load Connections 30 or 60 Amps Input / Output Connections GMT Fuse protected Load ConnectionsRelay Output Connections Relay J2 Connector Output Relay Notes Designations External Alarm Input ConnectionsRectifier Module Installation Initial Power-Up and CheckoutBattery and Load Power up Technical Description Rectifier ManagementControl Functions Alarm FunctionsSystem Management DisplaysBattery Temperature Compensation Battery ManagementBattery Charging Load ManagementBattery Low Voltage Disconnect Description MX06 Voltage AdjustmentsOperation MX06 OperationMX06-50 Configuration Settings MX06 External Alarm Input ConfigurationAlarm No Setting NC Setting Major Minor Factory Alarm MX06-50 Rectifier ConfigurationMX06-50 Programmable Alarms Major Minor No Alarm FactoryMX06-100 Configuration Settings MX06-50 Temperature Probe SelectionMX06-100 Rectifier Configuration MX06-100 Programmable Alarms MX06-100 Temperature Probe SelectionAC Input SpecificationsMX06 50 Power System TWF0500H5401 RectifierMX06 100 Power System DC OutputVDC Controls and Indicators MechanicalMX06 Controller Magnum VS 50 Power System Magnum VS 100 Power SystemEnvironmental Compliance EMCAPC Worldwide Customer Support Limited Product Warranty