American Power Conversion AP9604S Connecting Isolation Transformer, PE Cable, 370kW, 630 200 150

Page 62

Options/Accessories

6.6.1 Connecting Isolation Transformer

Isolation

UPS

 

External

External

 

External

External

External

Transformer

 

 

Input Fuses*

Input Cable

 

PE Cable

Output

Temp.

 

 

 

FM [A]

[mm2]

 

[mm2]

Cable

Signal Cable

 

 

 

380-415V

380-415V

 

 

 

[mm2]

[mm2]

280kVA

240kVA

500

 

2//125

 

100

 

2//125

2

 

 

 

 

 

 

 

 

 

 

 

*DIN gL types

 

 

 

 

 

 

 

 

 

 

PVC cables insulated to withstand a maximum ambient temperature of 30oC

 

 

 

 

 

 

 

 

 

 

 

Isolation

UPS

 

External

 

External

External PE

 

External

External

Transformer

 

 

Input

 

Input Cable

 

Cable

 

Output

Temp. Signal

 

 

 

Fuses* FM

 

[mm2]

 

[mm2]

 

Cable

Cable

 

 

 

[A]

 

380-415V

 

 

 

[mm2]

[mm2]

 

 

 

380-415V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

370kW

320kVA

 

630

 

2//200

150

 

2//200

2

 

 

 

 

 

 

 

 

 

 

 

*DIN gL types

PVC cables insulated to withstand a maximum ambient temperature of 30°C

990-4056

62

Installation Guide APC Silcon 240-320kW 400V UPS

Image 62
Contents 240-320kW 400V UPS Installation Guide Thank You Installation Guide APC Silcon 240-320kW 400V UPSSafety Symbols used in this manual Tools and Equipment IntroductionIntroduction ToolsUnpacking UnpackingRequirements on Site InstallationInstallation Height mm Width mm Depth mm1 1600mm Cabinet for 240-320kW UPS 2 825mm Cabinet for Isolation Transformer or Switch GearFootprint 3 1600mm Cabinet for 320kW Isolation Transformer External Connection Connecting the UPSExternal Connection Right side viewFuses* FM External External PE MaximumInput Cable External OutputSystem Integration Interface Connections Terminal Blocks X003/X004 Anxiliary Contacts X005 Output RelaysParallel Board Parallel BoardPower Cables External Control CablesRelay Board RelaysRelay Number Message Alarm-trigging Events Relay Board/Relay FunctionsSee .2 System configuration Communication Interface Board Connecting of APC Silcon Tripel Chassis Product Description Safety WarningsAPC Silcon Triple Chassis Monitoring PortLEDs Optional Power InputInstalling Management Peripherals If the LED is… Then the Silcon Triple Chassis…Management Peripheral Priority Position Card Installing Management Peripheral CardsOrder of Management Peripheral Cards Daisy-chaining the APC Silcon Triple ChassisManagement Peripheral Draw mA If Problems Persist TroubleshootingProblem Possible Cause Solution Product Specifications Monitoring Port Pin Assignments External Connection Power, Physical, and Environmental Specifications SpecificationAPC Silcon Battery Cabinets Important Safety InstructionsSilcon Battery Breaker Box/Fuse-boxInstallation of Batteries Battery Breaker Box HxWxD mm Ampere Connection Max Dimensions Weight Rating CableAPC Battery Breaker Box Connection Diagram 120-480kW CircuitExternal Connection Programming Parameters Parameter Setting CommentsProgramming Parameters ParametersProgramming Keys System Configuration Programming Example Switch to Bypass OperationSystem Configuration Parameters password protected Programming Example Change Charge Voltage to Programming Parameters Description of Settings Programming Parameters for Advanced Parallel OperationBattery Monitor Programming exampleProgramming Parameters Service Bypass Panel for Single Operation Options/AccessoriesOptions/Accessories Options/Accessories Display shows On Service Bypass PanelAction Lamp indicationSwitching from External Bypass to Normal UPS Operation Lamp indication On Servive Bypass PanelService Bypass Panel for Parallel Redundant Operation Two Parallel Systems with Service Bypass Panel Options/Accessories Options/Accessories Display shows H002a Lamp indication On Service Bypass Panel Following can be carried out on any UPS Isolating One UPS for Service/Maintenance Switching Back to Normal Parallel/Redundant OperationIntersystem Synchronization Unit ISU Intersystem Synchronization UnitIntersystem Synchronization Unit System ISU System Standard Short-haul RS232 Modem Async Remote DisplayExtension of Remote Display Communication Distance Connections With Converter Connections Without ConverterHost DTE Remote Display DTE Pin Connections for cable from host to ME800A-R2 HostRemote Display Power Supply Remote Display CablesAlarms Communication FaultRemote Display Setting Remote Display UseIsolation Height Width Depth WeightIsolation Transformer Example of Transformer Configuration Yyno 370kW Connecting Isolation TransformerPE Cable 630 200 150Options/Accessories Options/Accessories Options/Accessories Options/Accessories Options/Accessories Options/Accessories Technical Data System SpecificationsSystem Specifications Dimensions / WeightAPC Silcon Series Limited Factory Warranty WarrantyWarranty Appendix Installation Planning DataAppendix Appendix APC Corporate How to Contact APCHow to Contact APC APC Denmark